Digitale LCR -meter

  • RK2830/RK2837/RK2837A Digital Bridge

    RK2830/RK2837/RK2837A Digital Bridge

    RK2830
    Metingsparameters: | Z |, c, l, r, x, esr, d, q, θ
    Toetsfrekwensie: 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10 kHz
    Toetsvlak: 50MV-2.0V, resolusie: 10MV
    RK2837
    Metingsparameters: | Z |, c, l, r, x, | y |, b, g, esr, d, q, θ
    Toetsfrekwensie: 50Hz-100 kHz, 10MHz stap
    Toetsvlak: 10MV-1.0V, resolusie: 10MV
    RK2837A
    Metingsparameters: | Z |, c, l, r, x, | y |, b, g, d, q, θ
    Toetsfrekwensie: 50Hz-200 kHz, resolusie: 10MHz
    Toetsvlak: 10MV-2.0V, resolusie: 10MV

  • RK2839A/RKRK2839B/RK2839C Series Digital Bridge

    RK2839A/RKRK2839B/RK2839C Series Digital Bridge

    RK2839A
    Metingsparameters: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), Δ%
    Toetsfrekwensie: 20Hz-300kHz
    Toetsvlak: 5 mV -2V (standaardtipe); 5MV-10V (verbeter)
    Outomatiese vlakbereik: 5 mV -1V Akkuraatheid: 5% Resolusie: 1MV
    RK2839b
    Metingsparameters: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), Δ%
    Toetsfrekwensie: 20Hz-500kHz
    Toetsvlak: 5 mV -2V (standaardtipe); 5MV-10V (verbeter)
    Outomatiese vlakbereik: 5 mV -1V Akkuraatheid: 5% Resolusie: 1MV
    RK2839C
    Metingsparameters: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), Δ%
    Toetsfrekwensie: 20Hz-1MHz
    Toetsvlak: 5 mV -2V (standaardtipe); 5MV-10V (verbeter)
    Outomatiese vlakbereik: 5 mV -1V Akkuraatheid: 5% Resolusie: 1MV

  • RK2810A/RK2811D Digital Bridge

    RK2810A/RK2811D Digital Bridge

    RK2810A meetfunksie
    Metingsparameters: Hoof: L/C/R/Z Sub: D/Q/θ/ESR
    Basiese akkuraatheid: 0,20%
    Ekwivalente kring: reeks, parallel
    Afwykingsmetodes: 1%, 5%, 10%, 20%
    Bereikmodus: outomaties
    Meetfunksie
    Metingsparameters: Hoof: L/C/R/Z Sub: D/Q/θ/X/ESR
    Basiese akkuraatheid: 0,20%
    Ekwivalente kring: reeks, parallel
    Afwykingsmetodes: 1%, 5%, 10%, 20%
    Bereikmodus: outomaties, hou

  • RK2840A/RK2840B -reeks Digital Bridge

    RK2840A/RK2840B -reeks Digital Bridge

    RK2840A
    Metingsparameters: | Z |, c, l, r, x, | y |, b, g, d, q, θ, dcr
    Toetsfrekwensie: 20Hz-2MHz, resolusie: 10MHz
    Toetsvlak: F ≤ 1MHz, 10MV ~ 5V, resolusie: 10MV
    F > 1MHz, 10MV ~ 1V , Resolusie: 10MV
    RK2840b
    Metingsparameters: | Z |, c, l, r, x, | y |, b, g, d, q, θ, dcr
    Toetsfrekwensie: 20Hz-5MHz, resolusie: 10MHz
    Toetsvlak: F ≤ 1MHz, 10MV ~ 5V, resolusie: 10MV
    F > 1MHz, 10MV ~ 1V , Resolusie: 10MV

  • RK2811C Digital Bridge Tester

    RK2811C Digital Bridge Tester

    Hierdie digitale brugtoetser kan die elektriese parameters van verskillende komponente akkuraat meet.

  • RK2811D Digital Electric Bridge

    RK2811D Digital Electric Bridge

    RK2811D Digital Bridge is 'n nuwe generasie lae-frekwensie-komponent meetinstrument gebaseer op die nuutste meetbeginsel.
    Frekwensie: 100Hz, 120Hz, 1 kHz, 10 kHz
    Vlak: 0.1vrms, 0.3vrms, 1vrms
  • RK2830/ RK2837 Digital Bridge

    RK2830/ RK2837 Digital Bridge

    RK2830/ RK2837
    Frekwensie: 50 Hz, 60 Hz, 100 Hz, 120 Hz, 1 kHz, 10 kHz vlak: 50 mV - 2.0V
    Frekwensie: 50 Hz - 100 kHz, 10 MHz stapvlak: 10 mV - 1.0V
  • Facebook
  • LinkedIn
  • YouTube
  • Twitter
  • blogger
Produkte, Sitemap, Digitale hoogspanningsmeter, Spanningsmeter, Hoogspanning digitale meter, 'N instrument wat insetspanning vertoon, Hoë statiese spanningsmeter, Hoogspanningsmeter, Alle produkte