Ang RK9950 nga Programa nga Gikontrolar sa Leakage Current Tester
Overview sa Produkto
Ang Programmable Leakage Current Tester Usa ka 5-pulgada nga TFT LCD Display.Gisagop sa Tester ang 32-Bit High-Speed MCU Ug Dakong Digital Circuit Design,Gitukod Sa GB9706.1-2007 (IEC60601-1:1998) Body Impedance Simulation Network,Ang Card MD Network Interface Naglangkob sa MD-A (Nahiuyon sa GB/T12113-2003 Ug GB4793.1-2007), MD-B(Accord With GB/T12113-2003, GB4793.1-2007, GB4706.1-2005, GB4943.1-201898, GB4943.1-20189. -2015), MD-C(Accord With GB/T12113-2003,GB7000.1-2015),MD-D(Accord With GB4793.1-2007),MD-E(Accord With GB4943.1-2011,3GB. 1-2007)、MD-F(Accord With GB7000.1-2015) 。 Load Voltage Ug Current Overrun Protection;MD Network Multiple Fast Protection, Luwas Ug Kasaligan.Dynamic Ug Static Power Supply Test States;Ang Leakage Current Test Awtomatikong Gibalhin ang L (Phase Line) Ug N (Zero Line).Ang Setting Ug Operasyon Niini Yano Kaayo, Ug Naghatag PLC Remote Control Interface, RS232C, RS485, USB Ug Ubang mga Interface, Nga Sayon Alang sa Mga Gumagamit Aron Dali nga Maghiusa Ngadto sa Usa ka Komprehensibo nga Sistema sa Pagsulay.
Pag-pack ug Pagpadala
alang sa pakisayran .Unya paghimo sa pagbayad sumala sa imong gusto , sa diha nga ang pagbayad nakumpirma , kami maghikay sa shippment
sulod sa 3 ka adlaw.
gikumpirma.
1, Piho nga Parameter | |||||
Modelo | RK9950(Passive) | RK9950A(500VA) | RK9950B(1000VA) | RK9950C | |
Pangunang mga Katungdanan | Gidak-on sa Screen | 5-pulgada nga TFT LCD Screen | |||
Numero nga yawe | Pag-set sa Parameter Digital Input | ||||
Pagbalhin sa Coding | Pagpili ug Pagkumpirma sa Parameter Function | ||||
Taas, Pababa, Wala Ug Tuo Function Keys | Parameter Setting Up Ug Down Selection Function | ||||
LOCK Keyboard Locking Function | Paglikay sa Aksidente nga Pagbag-o sa mga Kondisyon sa Pagsulay O Pagdili sa Pagbag-o sa mga Kondisyon sa Pagsulay | ||||
Function sa Alarm | Alarm sa Tingog | ||||
Interface sa Komunikasyon | RS232C, RS485, USB | ||||
USB Interface | Kopyaha, Kopyaha Ug Pagtipig Mga Kalihokan | ||||
Pagkontrol sa Interface | HANDLER(PLC) | ||||
Pamaagi sa Pagsulay | Dinamiko, Static | ||||
Boltahe sa Pagkarga (AC) | Sakop | 0-300V | |||
Pagkatukma | + (2% ×Display Value +0.5V) | ||||
Frequency | 50/60Hz | ||||
Load Current(AC) | Maximum | 25A | |||
Labaw sa Kasamtang Proteksyon | Tingog Ug Kahayag nga Alarm, Putla ang Output sa Pagkarga | ||||
Kasamtangang Setting sa Leakage | Itaas nga Limitasyon Setting | ||||
Sakop | 0.001-20.00mA | ||||
Resolusyon | <10mA, 0.001/Lakang >10mA, 0.01mA/Lakang | ||||
Ubos nga Limitasyon Setting | |||||
Sakop | 0.000-20.00mA | ||||
Resolusyon | <10mA, 0.001/Lakang >10mA, 0.01mA/Lakang | ||||
Katin-awan | Ang Ubos nga Limitasyon Gitakda Sa 0 nga Wala’y Paghukom | ||||
Pagsukod sa Current Leakage | Range Ug Katukma | 0.001-0.050mA DC-10KHz | ± (5% × Display Value + 5 Words) | ||
0.050-20.00mA DC-10KHz | ± (2% × Display Value + 2 Words) | ||||
0.050-20.00mA 10KHz-1MHz | ± (5% × Display Value + 5 Words) | ||||
MD Simulated Human Network | 8 Sumbanan nga mga Network | MD-A(GB/T12113-2003,GB4793.1-2007),MD-B B1(GB/T12113-2003,GB4793.1-2007,GB4706.1-2005,1GB4943.1-8-2005 GB7000.1-2015), MD-C(GB/T12113-2003, GB7000.1-2015), MD-D (GB4793.1-2007), MD-E (GB4943.1-2011,70. ), MD-F(IEC60598-1:2014, GB4793.1-2007), MD-G(GB4943.1-2011, IEC60950-1:2005, GB4793.1-2007, 001-2007, IEC60950-1. | |||
Panahon sa Pagsulay | Sakop | Single Timing Test: 0.1-999s ± 1%;Ang Panapos nga Oras Mao ang Padayon nga Pagsulay | |||
Katin-awan | Kung Nagtakda sa 0S nga Pagsulay, N-Wire Lamang ang Gisulayan, Walay L Conversion | ||||
Gahum sa Output | Passive | 500VA | 1000VA | Tulo ka Phase Passive | |
Panggawas nga Power Supply | Eksternal nga Koneksyon | Gitukod sa | Gitukod sa | Eksternal nga Koneksyon | |
2, Kinatibuk-ang Technical Index | |||||
Kinatibuk-ang Teknikal nga Index | |||||
Temperatura ug Humidity sa Pagtrabaho | 0℃-40℃,≦75%RH | ||||
Suplay sa kuryente | 100V-121V, 198V-242V, 47.5-63Hz 5A 250V | ||||
Gidak-on sa Fuse | 5A 250V 10A 110V | ||||
Gawas nga Tomo(D×H×W) | 430mm × 105mm × 350mm | ||||
Gibug-aton | 13KG | 16KG | 18KG | 14KG |
Ang RK9950 nga Programa nga Gikontrolar sa Leakage Current Tester
MODELO | HULAGWAY | MATANG | SUMMARY |
RK995001 | Estandard | Ang Instrumento Gisangkapan Sa Standard Power Cable, Nga Mahimong Mapalit nga Gilain. | |
RK20K | Estandard | Ang Instrumento Gisangkapan Sa Standard Data Cable, Nga Mahimong Mapalit nga Gilain. | |
RK00001 | Estandard | Ang Instrumento Gisangkapan sa Standard Power Cord, Nga Mahimong Gipalit nga Gilain. | |
Sertipiko nga Warranty Card | Estandard | Instrument Standard Certificate Ug Warranty Card. | |
Sertipiko sa Calibration sa Pabrika | Estandard | Pag-calibrate sa Sertipiko sa Mga Produkto sa Instrumento. | |
Mga instruksyon | Estandard | Ang Manwal sa Operasyon Sa Instrumento Standard nga Produkto. | |
PC software | Kapilian | Ang instrumento adunay himan nga 16g U disk (lakip ang ibabaw nga software sa kompyuter). | |
RS232 ngadto sa USB cable | Kapilian | Ang instrumento nasangkapan sa RS232 hangtod sa USB cable (ibabaw nga kompyuter). | |
USB ngadto sa square port cable | Kapilian | Ang instrumento adunay gamit nga USB square port nga nagkonektar nga cable (ibabaw nga kompyuter). |