Mesurydd LCR Digidol

  • RK2830/RK2837/RK2837A Pont Ddigidol

    RK2830/RK2837/RK2837A Pont Ddigidol

    RK2830
    Paramedrau mesur: | Z |, C, L, R, X, ESR, D, Q, θ
    Amledd Prawf: 50Hz, 60Hz, 100Hz, 120Hz, 1KHz, 10kHz
    Lefel Prawf: 50mv-2.0v, Penderfyniad: 10mv
    RK2837
    Paramedrau mesur: | Z |, C, L, R, X, | Y |, B, G, ESR, D, Q, θ
    Amledd Prawf: 50Hz-100kHz, Cam 10MHz
    Lefel Prawf: 10mv-1.0v, Penderfyniad: 10mv
    Rk2837a
    Paramedrau mesur: | Z |, c, l, r, x, | y |, b, g, d, q, θ
    Amledd Prawf: 50Hz-200kHz, Penderfyniad: 10MHz
    Lefel Prawf: 10mv-2.0v, Penderfyniad: 10mv

  • RK2839A/RKRK2839B/RK2839C Cyfres Pont Ddigidol

    RK2839A/RKRK2839B/RK2839C Cyfres Pont Ddigidol

    RK2839A
    Paramedrau mesur: | Z |, R, X, DCR, | Y |, g, b, c, l, q, θ (deg), θ (rad), δ%
    Amledd Prawf: 20Hz-300KHz
    Lefel Prawf: 5 mV -2V (Math Safonol); 5MV-10V (Gwell)
    Ystod lefel awtomatig: 5 mv -1v Cywirdeb: 5% Datrysiad: 1mv
    Rk2839b
    Paramedrau mesur: | Z |, R, X, DCR, | Y |, g, b, c, l, q, θ (deg), θ (rad), δ%
    Amledd Prawf: 20Hz-500KHz
    Lefel Prawf: 5 mV -2V (Math Safonol); 5MV-10V (Gwell)
    Ystod lefel awtomatig: 5 mv -1v Cywirdeb: 5% Datrysiad: 1mv
    RK2839C
    Paramedrau mesur: | Z |, R, X, DCR, | Y |, g, b, c, l, q, θ (deg), θ (rad), δ%
    Amledd Prawf: 20Hz-1MHz
    Lefel Prawf: 5 mV -2V (Math Safonol); 5MV-10V (Gwell)
    Ystod lefel awtomatig: 5 mv -1v Cywirdeb: 5% Datrysiad: 1mv

  • RK2810A/RK2811D Pont Ddigidol

    RK2810A/RK2811D Pont Ddigidol

    RK2810A Swyddogaeth Mesur
    Paramedrau Mesur: Prif: L/C/R/Z Is: D/Q/θ/ESR
    Cywirdeb sylfaenol: 0.20%
    Cylchdaith gyfatebol: cyfres, paralel
    Dulliau gwyriad: 1%, 5%, 10%, 20%
    Modd Ystod: Awtomatig
    Swyddogaeth fesur
    Paramedrau Mesur: Prif: L/C/R/Z Is: D/Q/θ/X/ESR
    Cywirdeb sylfaenol: 0.20%
    Cylchdaith gyfatebol: cyfres, paralel
    Dulliau gwyriad: 1%, 5%, 10%, 20%
    Modd amrediad: awtomatig, dal

  • Cyfres rk2840a/rk2840b pont ddigidol

    Cyfres rk2840a/rk2840b pont ddigidol

    RK2840A
    Paramedrau mesur: | Z |, C, L, R, X, | Y |, B, G, D, Q, θ, DCR
    Amledd Prawf: 20Hz-2MHz, Penderfyniad: 10MHz
    Lefel Prawf: F ≤ 1MHz, 10mv ~ 5V, Penderfyniad: 10mv
    f > 1mhz, 10mv ~ 1v , datrysiad: 10mv
    Rk2840b
    Paramedrau mesur: | Z |, C, L, R, X, | Y |, B, G, D, Q, θ, DCR
    Amledd Prawf: 20Hz-5MHz, Penderfyniad: 10MHz
    Lefel Prawf: F ≤ 1MHz, 10mv ~ 5V, Penderfyniad: 10mv
    f > 1mhz, 10mv ~ 1v , datrysiad: 10mv

  • Profwr Pont Ddigidol RK2811C

    Profwr Pont Ddigidol RK2811C

    Gall y profwr pont ddigidol hwn fesur paramedrau trydanol gwahanol gydrannau yn gywir.

  • RK2811D Pont drydan ddigidol

    RK2811D Pont drydan ddigidol

    Mae Pont Ddigidol RK2811D yn genhedlaeth newydd o offeryn mesur cydran amledd isel yn seiliedig ar yr egwyddor fesur ddiweddaraf.
    Amledd: 100Hz, 120Hz, 1kHz, 10kHz
    Lefel: 0.1vrms, 0.3vrms, 1vrms
  • RK2830/ RK2837 Pont Ddigidol

    RK2830/ RK2837 Pont Ddigidol

    RK2830/ RK2837
    Amledd: 50 Hz, 60 Hz, 100 Hz, 120 Hz, 1 kHz, 10 kHz Lefel: 50mV - 2.0V
    Amledd: 50 Hz - 100 kHz, 10 MHz Lefel Cam: 10mv - 1.0V
  • Facebook
  • LinkedIn
  • YouTube
  • Twitter
  • blogwyr
Cynhyrchion dan sylw, Map Safle, Mesurydd foltedd uchel digidol, Fesurydd foltedd, Mesurydd digidol foltedd uchel, Offeryn sy'n arddangos foltedd mewnbwn, Mesurydd foltedd statig uchel, Mesurydd foltedd uchel, Pob Cynnyrch