Digital LCR Meter
-
Bridge RK2830 / RK2837 / RK2837A Digital
Rk2830
Pangukuran Parameter: | Z |, c, l, r, x, ESR, d, Q, θ
Frekuensi uji: 50Hz, 60Hz, 100HZ, 120Hz, 1kHz, 10kHz
Tingkat Tes: 50mv-2.0v, Resolusi: 10mv
Rk2837
Pangukuran Parameter: | Z |, c, l, r, x, | y |, b, g, g, q, q, θ
Frekuensi tes: 50hz-100KHz, 10mhz langkah
Tingkat test: 10mv-1.0v, Resolusi: 10mv
Rk2837a
Pangukuran Parameter: | Z |, c, l, r, x, | y |, g, g, d, q, θ
Frekuensi Tes: 50hz-200kHz, Resolusi: 10mhz
Tingkat test: 10mv-2.0v, Resolusi: 10mv -
RK2839A / RKRK2839B / RK2839C Series Digital Bridge
Rk2839a
Pangukuran Parameter: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), θ%
Frekuensi uji: 20Hz-300KHz
Tes level: 5 MV -2V (jinis standar); 5mv-10v (ditingkatake)
Rangkaian otomatis: 5 MV -1V akurasi: Resolusi 5%: 1MV
Rk2839b
Pangukuran Parameter: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), θ%
Frekuensi Tes: 20Hz-500khz
Tes level: 5 MV -2V (jinis standar); 5mv-10v (ditingkatake)
Rangkaian otomatis: 5 MV -1V akurasi: Resolusi 5%: 1MV
Rk2839c
Pangukuran Parameter: | Z |, r, x, dcr, | Y |, g, b, c, l, q, θ (deg), θ (rad), θ%
Frekuensi uji: 20Hz-1MHZ
Tes level: 5 MV -2V (jinis standar); 5mv-10v (ditingkatake)
Rangkaian otomatis: 5 MV -1V akurasi: Resolusi 5%: 1MV -
Jambatan digital RK2810A / RK2811d
Fungsi pangukuran rk2810E
Parameter Pangukuran: Main: L / C / R / Z Sub: D / Q / θ / Ésr
Akurasi dhasar: 0,20%
Circuit sing padha: Seri, Paralel
Cara nyimpang: 1%, 5%, 10%, 20%
Range Mode: Otomatis
Pangukuran fungsi
Parameter Pangukuran: Main: L / C / R / Z Sub: D / Q / θ / x / ESR
Akurasi dhasar: 0,20%
Circuit sing padha: Seri, Paralel
Cara nyimpang: 1%, 5%, 10%, 20%
Range Mode: Otomatis, Tahan -
RK2840A / RK2840B Series Digital Bridge
Rk2840a
Pangukuran Parameter: | Z |, c, l, r, x, | y |, b, g, d, θ, d, d, θ, d, d, d, d, d, d, d, d,
Frekuensi uji: 20Hz-2MHz, Resolusi: 10mhz
Tes Tes: F ≤ 1mhz, 10mv ~ 5V, Resolusi: 10mv
f> 1mhz, 10mv ~ 1v, Resolusi: 10mv
Rk2840b
Pangukuran Parameter: | Z |, c, l, r, x, | y |, b, g, d, θ, d, d, θ, d, d, d, d, d, d, d, d,
Frekuensi uji: 20Hz-5MHZ, Resolusi: 10mhz
Tes Tes: F ≤ 1mhz, 10mv ~ 5V, Resolusi: 10mv
f> 1mhz, 10mv ~ 1v, Resolusi: 10mv -
RK2811c Tes Gridge Digital RK2811c
Tester Bridge Digital iki bisa ngukur paramèter listrik saka macem-macem komponen.
-
Jembatan listrik digital RK2811d
Jembatan digital RK2811d minangka instrumen generasi frekuensi rendah sing anyar adhedhasar prinsip pangukuran paling anyar.Frekuensi: 100Hz, 120Hz, 1kHz, 10kHzTingkat: 0.1vrms, 0.3vrms, 1VRMS -
Jambatan digital RK2830 / RK2837
RK2830 / RK2837Frekuensi: 50 Hz, 60 Hz, 100 Hz, 120 Hz, 1 KHz, 10 KHZ Tingkat: 50MV - 2.0VFrekuensi: 50 hz - 100 khz, 10 mhz Langkah Langkah: 10mv - 1.0v