Hi-Pot Tester

  • RK9920-4C / RK9920-8C / RK9920A-8C / RK9920A-4C Tester Hipot

    RK9920-4C / RK9920-8C / RK9920A-8C / RK9920A-4C Tester Hipot

    Ev rêze bernameyê-kontrolkirî li hemberê testê voltaja testê ewlehiya ewlehiya performansa bilind e. RK9920-4C: 4 Testa berxwedana berxwedana înşeatê ya kanal: 0.05KV-1.00KV 0.1mω-10gω
    RK9920-8C: 8 Testa berxwedana berxwedana insulkirinê ya kanalan: 0.05KV-1.00KV 0,1mω-10gω
    RK9920A-8C: 8 Testa berxwedana berxwedana înşeatê ya kanalan: /
    RK9920A-4C: 4 Testa berxwedana berxwedana înşeatê ya kanalan: /
  • RK9914 / RK9914A / RK9914B / RK9914B / RK9914C / RK991515A / RK9915BER / RK9915B Kontrol kir

    RK9914 / RK9914A / RK9914B / RK9914B / RK9914C / RK991515A / RK9915BER / RK9915B Kontrol kir

    RK9914: AC (0.00 ~ 5.00) KV DC (0.00 ~ 6.00) KV AC 0 ~ 100ma; DC: 0 ~ 50ma

    IR: 0.10-5.00KV 100gω
    RK9914A: AC (0.00 ~ 5.00) KV DC (0.00 ~ 6.00) KV AC 0 ~ 100ma; DC: 0 ~ 50ma
    RK9914B: AC (0.00 ~ 5.00) KV AC 0 ~ 100ma
    RK9914C: AC (0.00 ~ 5.00) KV DC (0.00 ~ 6.00) KV AC 0 ~ 50MA; DC: 0 ~ 25ma

  • RK2674-50A / RK2674-50B / RK2674-100A / RK2674-100B Series Tester Voltage Voltage Vols Ultra

    RK2674-50A / RK2674-50B / RK2674-100A / RK2674-100B Series Tester Voltage Voltage Vols Ultra

    Testerê voltaja ultra-bilind ji bo ewlehiyê ye, li hember voltaja û leaksiyona heyî ya amûrên malbatê, hêzên hêzê, veguherîner, veguherîner, termînalên bilind û sîstemên voltaja bilind.

    RK2674-50A

    Range Test Voltage AC / DC: (0.00 ~ 50.00kv) KV

    Leakage Test Test Range AC 0 ~ 100ma DC: 0 ~ 20ma

    RK2674-50B

    Range Test Voltage AC / DC: (0.00 ~ 50.00kv) KV

    Leakage Test Range AC 0 ~ 100ma DC: 0 ~ 50ma

    RK2674-100A

    Range Test Voltage AC / DC: (0.00 ~ 100.00) KV

    Leakage Test Test Range AC 0 ~ 100ma DC: 0 ~ 20ma

    RK2674-100B

    Range Test Voltage AC / DC: (0.00 ~ 100.00) KV

    Leakage Test Range AC 0 ~ 100ma DC: 0 ~ 50ma

  • RK2674-15 / RK2674-AC20 / RK2674A / rk2674b / rk2674c

    RK2674-15 / RK2674-AC20 / RK2674A / rk2674b / rk2674c

     

    RK2674-15: AC / DC: 0-15KV
    AC: 0-2/20 / 40MA DC: 0-2 / 20MA
    RK2674-AC20 AC: 0-20kv
    AC: 0-2 / 20MA

    RK2674A: AC / DC: 0 ~ 20kv AC: 0 ~ 2 / 20ma DC: 0 ~ 2 / 10ma

    RK2674B: AC / DC: 0 ~ 30KV AC: 0 ~ 2 / 20ma DC: 0 ~ 2 / 10ma

    RK2674C: AC / DC: 0 ~ 50kv AC: 0 ~ 2/20 / 40MA DC: 0 ~ 2 / 20ma

    RK2674-50: AC / DC: 0 ~ 50 / 70kv

    RK2674-100: AC / DC: 0 ~ 100kv

  • Rk2672am / rk2672bm / rk2672cm / rk2672dm / rk2672df withstand voltaja test

    Rk2672am / rk2672bm / rk2672cm / rk2672dm / rk2672df withstand voltaja test

    The RK2672AM Bûyera voltaja voltaja ji bo berxwedana voltaja ye. performansa giştî wekî çavkaniyek voltaja bilind.

    RK2672AM: AC / DC: 0 ~ 5kv AC: 0 ~ 2 / 20ma DC: 0 ~ 2 / 10ma

    Rk2672bm: ac: 0 ~ 5kv ac: 0 ~ 2/20 / 100ma

    Rk2672cm: ac / dc: 0 ~ 5kv ac: 0 ~ 2/20 / 100ma DC: 0 ~ 2 / 20ma

    Rk2672dm: ac / dc: 0 ~ 5kv ac: 0 ~ 2/20 / 200ma DC: 0 ~ 2 / 20ma

    Rk2672df: AC / DC: 0-5KV TEST TEST: AC: 0-2/20 / 200ma

  • RK2670AM bi tester voltaja

    RK2670AM bi tester voltaja

    AC: 0 ~ 5kv AC: 0 ~ 2 / 20ma
  • RK9310 / RK9320 / RK9320A / RK9320B SERIES Serokwezîr AC / DC insulasyona AC / DC li hember tester voltaja

    RK9310 / RK9320 / RK9320A / RK9320B SERIES Serokwezîr AC / DC insulasyona AC / DC li hember tester voltaja

    RK9320 / RK9310
    AC / DC Bi Range Voltage Vittage: AC: 0.050KV ~ 5.000kv / DC: 0.050Kv ~ 6.000kv
    Rastiya voltaja: ± (2% + 5v)
    Mîhenga Voltage Voltapkirina Berxwedanê: 0,050KV ~ 5.000kv
    Mîhenga Sînorê ya Berxwedana Insulasyonê: Rêjeya: (0.2m ~ 100) g
    RK9320
    Hêza Hilberîna Mezintirîn: 100va (5.000kv / 20ma)
    Nirxandina herî zêde: 20ma
    RK9310
    Hêza Derveyî ya Mezin: 100VA (5.000kv /

  • RK2671E / RK2671EM Bi Tester Voltage Voltage

    RK2671E / RK2671EM Bi Tester Voltage Voltage

    Pêşkêşkirina hilberê The Merrick RK2671 Serûpelên li ser testerê voltaja-yê amûrek e ku ji bo pîvandina hêza voltaja ya li ser pîvanê ye. Ew dikare bi navgîn û zûtirîn û zûtirîn performansa ewlehiyê ya elektrîkê û leaksiyonê ya heyî ya cuda cuda ceribandin, û dikare wekî çavkaniyek bilind-voltaja were bikar anîn da ku performansa pêkhateyan û tevahiya makîneyê biceribîne. Ev rêze ceribandinan li gorî standardên jêrîn civiya: Standardên amûrên malê (IEC60 ...
  • RK9910 / RK9920 Insulasyona Kontrolkirî ya Kontrolkirî Bi Tester Voltage

    RK9910 / RK9920 Insulasyona Kontrolkirî ya Kontrolkirî Bi Tester Voltage

    Ev rêzefîlmên bernameyê yên li ser ceribandinên voltaja-ê ceribandinên ewlehiya performansa bilind in.
    Voltage Test: AC 0.05-5KV DC 0.05-6KV
    Test niha:
    (RK9910) AC: 0.001MA-10MA DC: 0.1A-5MA
    (RK9920) AC 0.001MA-20MA DC 0.1UA-10MA
  • RK9920AY / RK9910AY / RK9920BY / RK9920BY / RK9910BY Bûyera Intolage Voltage

    RK9920AY / RK9910AY / RK9920BY / RK9920BY / RK9910BY Bûyera Intolage Voltage

    RK9920AY: AC / DC: 0.05-5 / 6.00KV AC: 0.001MA-20MA DC: 0.1A-10MA

    RK9910AY: AC / DC: 0.05-5 / 6.00KV AC: 0.001MA-10MA DC: 0.1A-5MA

     

    RK9920By: AC: 0.05-5.00KV AC: 0.001MA-20MA

    RK9910by: AC: 0.05-5.00KV AC: 0.001MA-10MA

     

     

  • RK9970 / RK9970A-3 / RK9970A-6 Testerê Ewlekariya Auto Programbable

    RK9970 / RK9970A-3 / RK9970A-6 Testerê Ewlekariya Auto Programbable

    AC Bightstand Voltage Test Voltage Range: 0.050KV ~ 5.000kv

    AC Bêguman Voltaja Voltage Testa Rastiya: ± (1% + 0.2% ji pîvanê tevahî)

    Hêza herî zêde ya DC-ê ya DC-ê li hember testa voltaja: 120w (6.000kv / 20ma)

    Mîhenga voltaja voltapkirinê ya insulasyonê: 0,050kv ~ 5 000kv Resolution: 1v Volts / gav

    Rêjeya berxwedana erdê ya heyî: (3.0-32.0) a

    Rastiya heyî: ± (1% nirxa xwendinê + 0.2a)

    Rêza Voltage Hêza: 30.0V ~ 300.0V

    Rêzeya voltaja heyî ya leakage: 30.0V ~ 300.0V

    Rastiya voltaja kêm-voltaja kêm: ± (1% nirxa xwendinê + 2V)

    Kevneşopiya voltaja kêm a Voltage: 30.0V ~ 300.0V

  • RK9974-10 / RK9974-20 / RK9974-30 / RK9974-30

    RK9974-10 / RK9974-20 / RK9974-30 / RK9974-30

    Ev ceribandinên voltaja ultra-bilind ên kontrolkirî ji bo peydakirina voltaja bilind û analîzê ji bo optocouplên voltaja bilind, relikên bilind, guhêrbarên voltaja bilind, modulên voltaja bilind û amûrên din ên bi berxwedana insulasyona bilind.

    RK9974-10 AC 200VA (10.0KV 20MA) DC 100VA (10.0KV 10MA)

    RK9974-20 AC 400VA (20.0KV 20MA) DC 200VA (20.0KV 10MA)

    RK9974-30 AC 600VA (30.0KV 20MA)

    RK9974-50 AC 1000VA (50.0kv 20MA)

     

     

     

     

  • RK2671DM Bi Testerê Voltage Voltage

    RK2671DM Bi Testerê Voltage Voltage

    RK2671DM Li hemberê voltaja voltaja amûrek e ku ji bo pîvandina li hember hêza voltaja.

    AC / DC: (0.00 ~ 10.00) KV

    2Ma, 20ma, 100ma

     

  • RK9920-16C / RK9920-32C AC û DC li hember ceribandina insulasyona voltaja

    RK9920-16C / RK9920-32C AC û DC li hember ceribandina insulasyona voltaja

    Ev rêzefîlmên bernameyê yên li ser ceribandinên voltaja bi lez û bez dikarin pîvandinên ewlehî yên berfireh ên li ser amûrên malê, amûrên ronahiyê, amûrên germkirinê yên elektrîkê, komputer û agahdariyê bikin.

    RK9920-16C: 16-rê bi testa voltaja ya têkildar: Voltaja Derketinê AC: 0.05KV ~ 5.00kv ± 2%
    RK9920-32C: 32-rê bi testa voltaja-ya têkildar: Voltaja Derketinê AC: 0.05KV ~ 5.00kv ± 2%

  • RK2672E / EM Bêhna Testê Insulasyona Voltage

    RK2672E / EM Bêhna Testê Insulasyona Voltage

    The RK2672e / em li hemberê voltaja Mezin e, amûrê pîvanê ye.
    AC: 0 ~ 5kv
    DC: 0 ~ 6kv
    AC: 0 - 2/20 / 200/500 MA (± 5% + 3 bêjeyên)
    DC: 0 - 2/20 / 200 MA (± 5% + 3 bêjeyên)
  • RK9910-4U / 8U Paralel Multi-Unit Tester HPOT

    RK9910-4U / 8U Paralel Multi-Unit Tester HPOT

    RK9910-4U / RK9910-8U

    AC: 0.05KV ~ 5.00KV ± (1% + 5 tîp)

    DC: 0.05Kv ~ 6.00Kv ± (1% + 5 tîp)

    RK9910-4U / RK9910-8U

    Ac: 1 ~ 20ma

    DC: 1 ~ 20ma

  • RK2671AM / RK2671BM / RK2671CM Bi Tester Voltage Voltage

    RK2671AM / RK2671BM / RK2671CM Bi Tester Voltage Voltage

    AC / DC: 0 ~ 5 / 10kv

    RK2671AM: AC: 0 ~ 2 / 20ma DC: 0 ~ 2 / 10ma

    Rk2671bm: AC: 0 ~ 2/20 / 50Ma DC: 0 ~ 2 / 20ma

    RK2671CM: AC: 0 ~ 2/20/20 / 100MA DC: 0 ~ 2 / 20ma

     

  • RK9910B / RK9910B / RK9920A / RK9920B Programbable Bi Tester Voltage Voltage

    RK9910B / RK9910B / RK9920A / RK9920B Programbable Bi Tester Voltage Voltage

    RK9910A / rk9920a:

    AC: 0.05-5.00 DC: 0.05-6.00KV

    AC: 0.001MA-10MA
    DC: 0.1UA-5MA

    AC: 0.001MA-20MA
    DC: 0.1UA-10MA

  • RK7112 / RK7122 / RK7110 / RK7120 Programbable Bi Tester Voltage Voltage

    RK7112 / RK7122 / RK7110 / RK7120 Programbable Bi Tester Voltage Voltage

    RK7112: AC: 0-5KV 0.10-12.00MA
    RK7122: AC: 0-5KV DC: 0-6KV AC: 0.10-12.00MA DC: 0.10-5.00MA
    RK7110: AC: 0-5KV 0.10-12.00MA
    RK7120: AC: 0-5KV DC: 0-6KV AC: 0.10-12.00MA DC: 0.10-5.00MA
  • Facebook
  • LinkedIn
  • youtube
  • Twitter
  • Blogger
Hilberên Taybet, Nexşe, Metertê Voltaja, Metera Voltage High Voltage Digital, Metreya voltaja bilind, Metra Voltage High, Metre dîjîtal a voltage bilind, Amûrek ku voltaja input nîşan dide, Hemî hilber

Peyama xwe ji me re bişînin: