Summus Potestas DC Electronic Load
Programmabile DC electronicum pondus habet 200V, 600V et 1200V intentione consilia, et ultra-altae potentiae densitas.Support 4 genera CV/CC/CR/CP Methodi fundamentales operandi, et III genera CV+CC/CV+CR/CR+CC Methodi composita.Cum Plus-Current, Plus Potentia, Plus Temperaturae Admonitio Et Sustentatio Munerum, Super-Voltage, Reverse Connection Admonitio Function, Prospicere potest Sustentationem.Suscipe externam 0~10V analogiam intentione signum moderari / moderari Waveform voltage aut Current signum ab 0 ad scalam.Support OCP/OPP Function Inspection, Support Sequence Correction And Nuntius Inspection Opus curva.Support OCP/OPP Function Inspection, Support Sequence Correction And Nuntius Inspection Opus curva.Magister-Servus/Syncronous Control Modus Active Expands Onus Capacitas.Standard RS232/RS485/USB Methodus Communicationis, LAN&GPIB libitum.Late adhiberi potest in altilium missione, DC incurrentes sublicis, potentia electronicis et aliis locis inspectionis Product.
Eget Commodum
1. Reversible Panel et LAETUS Tactus Screen
Haec series Programmabilium DC Electronic Loads (exceptis aliquot exemplaribus) sustinet frontem Panel Flip Function, et instructus magna LAETUS Tactus Screen Praebere Customers Cum Simplex et Commoda Operatione, Real-Tempus Update Input Flashing Et Equipment Status, Et Graphics Facere Flashing More Intuitive.
2. Multiplex Operatio Methodi
In hac serie programmabilium DC electronicarum onera CV/CC/CR/CP Basic Load stabilis methodi publicae, quae variarum occasionum inspiciendarum necessitatibus occurrere possunt.
3. Novifacta Responsio celeritas CV loop
Haec series Programmabilium DC Electronic Loads Poni potest Cum tribus intentione Responsionis Celeritatis Fasti, Medii Et Tardi Ad Compositionem Variae Propriae Virtutis Supplies.
Hoc munus impedire mensurae accuratae Gutta aut Inspectio culpae causatur cum onus et potestas responsionis celeritas non congruit, et potestas inspicitur reducere sumptus apparatum, tempus et expensas.
Quattuor, Methodus inspectionis Dynamicae
Haec series programmabilium electronicarum onera cito commutare potest inter varias valores sub eodem munere, et subsidia Dynamica Current, Dynamica Voltage, Dynamica Resistentia et Methodi Dynamicae potentiae, inter quas Resistentia Dynamica et Methodi Dynamica Resistentia pervenire potest 50kHz.
Haec Functio adhiberi potest ad reprimendam Notas Dynamicas Virtutis Supple, Pugna Sustentationem Characteres, Pugna Pulsus Incurrentes, Etc. Dynamic Load Reperiens Function Praebere tres modos Connectionis, Pulsus et Flip.
5. Zhengxuan non est firma in Lond
Haec series Programmabilium Electronic Loads sustinet functionem Sine Unda Sourcing Current et applicari potest Impedimento Analysis Fuel Cellae.
Sex, Dynamic Frequency Conversio ENARRATIO Function
Hanc seriem Programmabilium DC Electronic Loads subsidia Dynamica Frequency Conversionis ENARRATIO Function, quae frequentia Conversionis utitur methodo ad inveniendum pessimum DUT Voltage.
Usoris ponit parametri post Correctionem Duo Constant Current Valores, Incipiens Frequentiam, Perpetuus Frequentia, Gradus Frequentia, Tempus Morandi Et Aliae Parametri.
The Sampling Rate of the Dynamic Frequency ENARRATIO Function Possit pervenire 500kHz, Quod imitari varias Load Conditiones et Meet Inspectionis Requisita.
Septem, Pugna inspiciendi officii sint
In hac serie electronicarum onera uti possunt CC, CR vel CP Methodi Ad Pugnam Exsolvere, Et Accurate Pone Et Metire Abscise intentionem Vel Dimissionem Tempus Curandi Ut Pugna non laedatur Ob Immodica Dimissionem.
Dimissio abscise condicio secundum necessitates practicas constitui potest.Cum abscisae condicio occurrit, onus continue evellitur et Timor absistit.
Per Inspectionis Processus, Parametris Ut Pugna intentione, Tempus solvendi Et Capacitas Potest etiam Monitored in Real Tempus.
8. Active inspection
Haec series electronicarum onera potest active switched sub coercitionibus Of CV, CR, CC et CP Methodi, et apta est inspectioni Lithii Electronic Pugna scutariorum Ad obtinendum Ignitum VI Curve Charging.
Inspectio activa et activa methodus potentiam operationem augere potest multum.
Novem, OCP/OPP Inspectionis
OCP/OPP Inspectio Items suppleta per hanc seriem programmabilium DC electronicarum onera peragere possunt congue comprobatio super-currentis sustentationis/per-potestatis sustentationem.Terminum valorem praeponitur inspectioni, et effectus inspectionis Automatarie emicuit admonere Customers post inspectionem.
Inspectio OPP Inspectio, Exemplum, Onus Inspectio Resurgens Ramp Potestas Ad Reprimendam An Output intentione Objecti Sub Test infra De Trigger Voltage Cum onustum, Et Judicium Utrum Output Sustentationem Function Obiecti Sub Test Works Communiter.
Decem, Sequentiae Methodus Function
Haec series electronicarum onera habet functionem electronicae Sequentiae Methodi, quae active Imitare potest Messy Mutationes oneris, Secundum Sequentiae Tabulae correctae User.
Sequentia Methodus Continet 10 Tabularum Propositas, Et Profectus Parameters Includere Inspectionis Methodum (CC, CV, CR, CP, Brevis Circuitus, Switch), Numerus cyclorum, Numerus Sequentiae Graduum, Singulus Gradus Ponens Valorem Et Single Gradus Tempus, etc.
Hanc Function Can cohibere Virtutem Output Characteres, Moderare Stabilitas Potestatis Supple Et Imitare Conditiones Actuales.
11. Magister Servus Imperium
Hanc seriem Programmabilium DC Electronic Loads sustinet Methodi Magistri servi, Parallel Operationem electronicarum onera electronicarum ejusdem intentionis, et Synchroni Edidit.
In Usu, Solus Magister moderatur, Et Magister Computat Et Distribuit Current Ad Cetera Servi onera.Unus magister cum servis multiplicibus pro amplioribus oneribus idoneus est et magnopere significat processum operationis User.
12. Programming externa et Current / intentione Cras
Haec series programmabilium electronicarum onera moderari potest onera intentione et currenti per analogiam input externam.Externi potenti signum 0~ 10V respondet oneris 0~ plenae oneris conditionis.
Input intentione moderata per analogam externam quantitatis absolvere potest conditiones arbitrii arbitrii Waveforms, quae Meets Requirements Industrialis Imperii.
Current / intentione Cras output Terminal outputs Current / intentione respondet 0 ~ plena magnitudine cum 0 ~ 10V analogon quantitate.Externus voltmeter aut oscilloscope coniungi potest Monitori Current/Voltages Mutationes.
Post tempus: Feb-06-2021