Pulagi Yoyambirira ya Factory China mu 12W Zotulutsa AC100V- 240V Adapter Kusintha Mphamvu
Timakhulupilira mu: Kupanga nzeru ndi moyo wathu ndi mzimu.Ubwino ndi moyo wathu.Chosowa chamakasitomala ndi Mulungu wathu wa Pulagi Yoyambira Factory China mu 12W Output Input AC100V- 240VAdapterKusintha Magetsi, Tikufuna kungotenga mwayiwu kuti tidziwe ubale wanthawi yayitali wamabizinesi ndi makasitomala ochokera padziko lonse lapansi.
Timakhulupilira mu: Kupanga nzeru ndi moyo wathu ndi mzimu.Ubwino ndi moyo wathu.Zosowa zamakasitomala ndi Mulungu wathuAdapter, China Kusintha Mphamvu Supply, Yang'anani m'tsogolo, tidzaganizira kwambiri za zomangamanga ndi kukwezedwa .Ndipo popanga mtundu wathu waukadaulo wapadziko lonse lapansi timalandira mabwenzi ochulukirachulukira kuti agwirizane nafe, gwirani ntchito limodzi nafe potengera kupindula.Tiyeni tikweze msika pogwiritsa ntchito mokwanira maubwino athu ambiri ndikuyesetsa kumanga.
Chiyambi cha Zamalonda
Timakhulupilira mu: Kupanga nzeru ndi moyo wathu ndi mzimu.Ubwino ndi moyo wathu.Zosowa zamakasitomala ndi Mulungu wathu wa Pulagi Yoyambira Factory China mu 12W Output Input AC100V- 240V Adapter switching Power Supply, Tikufuna kungotenga mwayiwu kutsimikizira ubale wanthawi yayitali wamabizinesi ndi makasitomala ochokera padziko lonse lapansi.
Factory YoyambiriraChina Kusintha Mphamvu Supply, Adapter, Yang'anani zamtsogolo, tidzayang'ana kwambiri pakupanga mtundu ndi kukwezedwa .Ndipo popanga mtundu wathu waukadaulo wapadziko lonse lapansi timalandira mabwenzi ochulukirachulukira kuti agwirizane nafe, gwirani ntchito limodzi nafe potengera kupindula.Tiyeni tikweze msika pogwiritsa ntchito mokwanira maubwino athu ambiri ndikuyesetsa kumanga.
Chitsanzo | KPS1660 | KPS3220 | KPS3232 | KPS6011 | KPS6017 |
Operating Voltage Range | 170/264Vac | 170/264Vac | 170/264Vac | 170/264Vac | 170/264Vac |
Opaleshoni Frequency Range | 45-65HZ | 45-65HZ | 45-65HZ | 45-65HZ | 45-65HZ |
Kutulutsa kwa Voltage Range | 0-16 V | 0-32 V | 0-32 V | 0-60 V | 0-60 V |
Linanena bungwe Current Range | 0-60A | 0-20A | 0-32A | 0-11A | 0-17A |
Kuchita bwino (20 Katundu Wonse) | ≥89% | ≥88% | ≥88% | ≥89% | ≥89% |
Katundu Wathunthu Pakalipano (220VAC) | ≤5.1A | ≤5.1A | ≤3.3A | ≤3.35A | ≤5.1A |
Palibe Katundu Pakalipano (220VAC) | ≤180mA | ≤180mA | ≤180mA | ≤180mA | ≤180mA |
Kulondola kwa Voltmeter | ≤0.3% +1 manambala | ≤0.3% +1 manambala | ≤0.3% +1 manambala | ≤0.3% +1 manambala | ≤0.3% +1 manambala |
Kulondola kwa Ammeter | ≤0.3% + 2 manambala | ≤0.3% + 2 manambala | ≤0.3% + 2 manambala | ≤0.3% + 2 manambala | ≤0.3% + 2 manambala |
Kulondola kwa Meter Meter | ≤0.6% + 3 manambala | ≤0.6% + 3 manambala | ≤0.6% + 3 manambala | ≤0.6% + 3 manambala | ≤0.6% + 3 manambala |
Constant Pressure State | |||||
Mlingo Wowongolera Katundu (0 ~ 100%) | ≤30mV | ≤30mV | ≤30mV | ≤30mV | ≤30mV |
Kulowetsa kwa Voltage Regulation Rate (198 ~ 264Vac) | ≤10mV | ≤10mV | ≤10mV | ≤10mV | ≤10mV |
Phokoso la Ripple (Peak-Peak) | ≤30mV | ≤30mV | ≤30mV | ≤30mV | ≤30mV |
Phokoso la Ripple (RMS) | ≤3mV | ≤3mV | ≤3mV | ≤3mV | ≤3mV |
Ikani Zolondola | ≤0.3% + 10mV | ≤0.3% + 10mV | ≤0.3% + 10mV | ≤0.3% + 10mV | ≤0.3% + 10mV |
Nthawi Yoyankha Nthawi yomweyo(50% -10% Adavoteredwa Katundu) | ≤1.0ms | ≤1.0ms | ≤1.0ms | ≤1.0ms | ≤1.0ms |
Constant Current State | |||||
Mtengo Wowongolera Katundu (90% -10% Yovotera Voltage) | ≤50mA | ≤50mA | ≤50mA | ≤50mA | ≤50mA |
Kulowetsa kwa Voltage Regulation Rate (198 ~ 264Vac) | ≤20mA | ≤20mA | ≤20mA | ≤20mA | ≤20mA |
Ripple Current Noise (PP) | ≤30mAp-P | ≤30mAp-P | ≤30mAp-P | ≤30mAp-P | ≤30mAp-P |
Kukhazikitsa Zolondola | ≤0.3% +20mA | ≤0.3% +20mA | ≤0.3% +20mA | ≤0.3% +20mA | ≤0.3% +20mA |
Kukula (M'lifupi * Kutalika * Kuzama) | 160 * 75 * 215mm | 160 * 75 * 215mm | 160 * 75 * 215mm | 160 * 75 * 215mm | 160 * 75 * 215mm |
Kalemeredwe kake konse | 2.5KG | 2KG pa | 2.5KG | 2KG pa | 2.5KG |
Chitsanzo | Chithunzi | Mtundu | Chidule |
RK00001 | Kusintha kokhazikika | Chidacho Chili Ndi Chingwe Champhamvu cha American Standard Power, Chomwe Chingathe Kugulidwa Payokha. | |
Operation Manual | Kusintha kokhazikika | Operation Manual Of Standard Equipment
|