RK2670YM/RK2672YM/RK2672CY/RK2671AY Medical Withstand Voltage Tester
RK2672CY Medical Withstand Voltage Tester
product description
RK2672CY medical withstand voltage tester has all the functions of the conventional withstand voltage tester, and adds the arc (flashover) detection function. Through an external oscilloscope, it can intuitively, accurately, quickly and reliably detect the "flashover" of the electrical equipment under test. When the electrical equipment under test has no "flashover" phenomenon, the oscilloscope displays a stable "Lissayut graph (that is, a closed circle)". If the electrical equipment under test has a "flashover" phenomenon, the edge of the Lissajous waveform A jagged shape will appear, indicating that there is a "flashover" inside the electrical equipment under test. This product is also suitable for various electrical equipments that need to detect "flashover" defects. It is an indispensable withstand voltage tester for medical electrical equipment manufacturers, maintenance departments, users, product quality inspection departments, and technical supervision departments.
Application field
Medical equipment: all kinds of new medical equipment and medical supporting equipment, cardiac monitoring, medical imaging, biochemical analysis equipment, blood pressure monitors and thermometers and other home medical equipment
Diagnosis and treatment equipment: X-ray diagnosis and examination equipment, ultrasound diagnosis, nuclear medicine, endoscopy system, ENT diagnosis and treatment equipment, dynamic analysis diagnosis and treatment equipment, low temperature refrigeration equipment, dialysis diagnosis and treatment equipment, first aid equipment
Hospital nursing equipment and appliances: all kinds of beds, cabinets, surgical chairs, beds, etc.
Auxiliary equipment: medical nursing data and image processing equipment, rehabilitation equipment, special equipment for the disabled, etc.
Oral medical equipment: dental diagnostic medical equipment, dental surgical equipment, dental technician equipment
Medical Magnetic Resonance Equipment
Performance characteristics
1. The test time can reach 999s
2. Leakage current, voltage and time are displayed at the same time
3. Leakage current, test time can be set continuously
4. With oscilloscope interface, it can monitor the phenomenon of ignition arc and flashover of the object under test
5. GB9706.1-2020 (IEC60601-1:2012) test voltage requirements: no flashover or breakdown should occur during the test. The medical withstand voltage tester has specially added an oscilloscope interface to observe the flashover and arc phenomenon through Lissajous graphics.
Packing&Shipping


for reference .Then make payment as the way you like , as soon as the payment have been confirmed ,we will arrange shippment
within 3 days .
been confirmed.
type | RK2672CY | RK2670YM | RK2672YM | RK2671AY | |
ACW | Output voltage range | (0.00~5.00)kV | (0.00~10.00)kV | ||
Maximum output power | 500VA(5.00kV 100mA) | 100VA(5.00kV 20mA) | 100VA(5.00kV 20mA) | 200VA (10.0kV/20mA) | |
Maximum rated current | 100mA | 20mA | 20mA | 20mA | |
Current gear | 2mA、20mA、100mA | 2mA、20mA | 2mA、20mA | 2mA、20mA | |
Output waveform | sine wave | ||||
Output waveform distortion | ≤5% (no-load or pure resistance load) | ||||
testTime | 0.0S-999S 0= continuous test. | ||||
DCW | Output voltage range | (0.00~5.00)kV | / | (0.00~5.00)kV | (0.00~10.0)kV |
Maximum output power | 100VA(5.00KV 20mA) | 50VA(5.00KV 10mA) | 100VA(10.0KV/10mA) | ||
Maximum rated current | 20mA | 10mA | 10mA | ||
Current gear | 2mA、20mA | 2mA、10mA | 2mA、10mA | ||
ripple factor | ≤5% | ≤5% | ≤5% | ||
testTime | 0.0S-999S 0= continuous test. | 0.0S-999S 0= continuous test. | 0.0s ~ 999s0.0 = continuous test. | ||
voltmeter | range | (0.00~5.00)kV | (0.00~5.00)kV | (0.00~5.00)kV | (0.00 ~10.0KV ) |
precision | +/-(5%+3 words) | ||||
resolution ratio | 10V | ||||
Display numerical value | root mean square value | ||||
galvanometer | measuring range | Range 1: 0.1ma ~ 2ma Range 2: 2ma ~ 20ma Range 3: 20ma ~ 100ma |
Range 1: 0.1ma ~ 2ma Range 2: 2ma ~ 20ma |
Range 1: 0.100ma ~ 2ma Range 2: 2ma ~ 20ma |
|
DC | 0.1mA~2mA | / | 0.1mA~2mA | 0.100mA~2mA | |
2mA~20mA | 2mA~10mA | 2mA ~10mA | |||
resolution ratio | 2mA file: 1uA;; 20mA gear: 10uA;; 100mA gear: 0.1mA |
2mA file: 1uA;; 20mA gear: 10uA |
2mA file: 1uA;; 20mA gear: 10uA |
2mA file: 1uA;; 20mA gear: 10uA;; 50mA(100mA) gear: 0.1mA |
|
measurement accuracy | Within the range of (5%+3 words) | ||||
Test range | 0.0S-999S 0= continuous test. | ||||
timer | range | 0.0S-999S | 0.0S-999S 0.0 equals continuous testing. | 0.0s~999s | |
Minimum resolution | 0.1S | / | 0.1s | ||
precision | ±(1%+50ms) | ±(1%+50ms) | |||
transformer capacity | 500VA | 100VA | 200VA (10.0kV/20mA) | ||
power requirement | AC:220V±10% 50Hz/60Hz±3Hz | ||||
working environment | Temperature: (0-40)℃ Humidity ≤75%RH | ||||
PLC interface | select to breed | ||||
External control interface | standard configuration | ||||
Overall volume (D×H×W) | 407*199*378mm | 318*253*178mm | 313*248*175mm | 378*278*197mm | |
weight | 20.45KG | 9.75KG | 10.35KG | 15.35Kg | |
Standard attachment | Power line RK00001, high voltage test line, grounding line, BNC line, high-voltage gun. | ||||
select to breed | PLC interface, RK101 series spot check box |
High Accuracy AC 5KV & AC 100mA Dielectric Withstand Voltage puncture tester / Hipot Tester
Model |
Picture |
Type |
|
RK-16G |
|
Standard |
Test Gun |
RK260100 |
|
Standard |
Test Wire |
RK26103 |
|
Standard |
Ground Lead |
Power Cord |
|
Standard |
|
Warranty Card |
|
Standard |
|
Factory Calibration Certificate |
|
Standard |
|
Manual |
|