RK2675YM series medical leakage current tester

Output voltage range: 0-300V
Test current: AC/DC: 0-200uA AC/DC: 0.2-2mA AC: 2-10mA
Test accuracy: ± 5%+3 words
Test time: 0-99S (continuously adjustable)


Description

Technical parameter

Accessories

Product Introduction
The ordinary leakage current tester, also known as the contact current tester, is used to measure the leakage of electrical appliances that is not related to work caused by insulation or distributed parameter impedance of the working power supply (or other power sources). Its input impedance simulates the impedance of the human body and meets the requirements of GB4706.1 and GB9706.1-2020. The RK2675YM series medical leak tester products are designed in accordance with international and domestic safety standards such as IEC, ISO, BS, UL, JIS, etc. Leakage current alarm values can be continuously and arbitrarily set according to different safety standards and user needs;
application area
1. Medical equipment: various types of new medical instruments and medical supporting instruments, cardiac monitoring, medical imaging, biochemical analysis instruments, blood pressure monitors and thermometers, and other home medical equipment
2. Diagnostic and therapeutic equipment: X-ray diagnostic examination equipment, ultrasound diagnosis, nuclear medicine, endoscopic system, facial features treatment equipment, dynamic analysis treatment equipment, low-temperature freezing equipment, dialysis treatment equipment, emergency equipment
3. Ward nursing equipment and appliances: various types of beds, cabinets, operating chairs, beds, etc
4. Auxiliary equipment: medical nursing data and image processing equipment, rehabilitation equipment, disability specific equipment, etc
5. Oral medical equipment: dental diagnostic medical equipment, dental surgical instruments, dental technician equipment, medical magnetic resonance equipment
Performance characteristics
1. Test circuit (MD). Range change unit
2. It is convenient for users to choose the appropriate range according to the actual load size
3. The display module displays the test voltage, actual leakage current, and test time
4. The over limit alarm circuit completes the alarm and indication of non standard products and automatically cuts off the output power supply
5. The experimental voltage adjustment device can adjust the appropriate test voltage according to different standards


  • Previous:
  • Next:

  • Model RK2675YM RK2675YM-1 RK2675YM-2 RK2675YM-3 RK2675YM-5
    Test Voltage 0~300V
    Test Current AC/DC:0~200μA  AC/DC:0.2~2mA  AC:2~10mA
    Test Accuracy ±5%
    Test Time 0~99s (Adjustable Continuously)
    Transformer Capacity 500VA 1000VA 2000VA 3000VA 5000VA
    Output Waveform Sine Wave
    Power requirements 220V  ±10%50Hz  2%
    Working environment 0℃~40℃ ≤85%RH
    Exterior Dimension(mm) 375*280*200mm 375*280*200mm 430X380X200mm 430X380X200mm 505X470X270mm
    Weight 14Kg 19.6Kg 34.8Kg 41.5Kg 73.2Kg
    Accessory Power Line,Alligator Clip

    Send your message to us:

    Write your message here and send it to us
    • facebook
    • linkedin
    • youtube
    • twitter
    • blogger
    Featured Products, Sitemap, Digital High Voltage Meter, Voltage Meter, High-Voltage Digital Meter, High Voltage Meter, High Static Voltage Meter, An Instrument That Displays Input Voltage, All Products

    Send your message to us:

    Write your message here and send it to us