RK2678YM Medical Grounding Resistance Tester
Product Introduction
RK2678YM Medical Grounding Resistance Tester Is Used To Measure The Internal Electrical Equipment Of Grounding Resistance,Which Reflects The (Contact) Resistance Of Total Grounding Terminal Of Electrical Equipment.It Suitable For Measuring All Kinds Of Motors,Electrical Appliances,Instruments,Household Appliances And Other Equipment Resistance Between The Shell And The Grounding Wire.
It According With The Medical Standard Of GB9706.-2020(IEC60601-1:2012) .
Application Area
Medical Equipment:all Kinds Of New Medical Instrument And Medical Equipment Matched, Cardiac Monitoring,Medical Imaging,Biochemical Analysis Instruments,Blood Pressure Meter And Thermometer And Other Types Of Home Medical Equipment.
Diagnosis And Treatment Equipment:X-Ray Diagnosis And Examination Equipment,Ultrasound Diagnosis,Nuclear Medicine,Endoscope System,ENT Treatment Instrument,Dynamic Analysis Treatment Equipment And Low Temperature Refrigerating Equipment,Dialysis Treatment Equipment,First-Aid Equipment.
Ward Nursing Equipment And Equipment:all Kinds Of Hospital Bed,Cabinets,Operating Chairs,Beds,Etc.
Auxiliary Equipment:medical Care Data And Image Processing Equipment,Rehabilitation Equipment And Special Equipment For The Disabled Etc.
Oral Medical Instrument And Equipment:dental Diagnostic Medical Equipment,Dental Surgical Instruments,Dental Technician Equipment.
Medical Magnetic Resonance Equipment
Performance Characteristics
Test Time,Test Current And Grounding Resistance Display At The Same Time.
Leakage Alarm Resistance Values Can Be Preset Continuously,It Is More Convenient To Influence Of Test,It Is National Initiative.
Four End Measuring Method Is Adopted To Eliminate The Influence Of The Contact Resistance On The Test.It Has High Test Accuracy.
Add Open Selection Tool Of Circuit Alarm,The User Can Open The Alarm Freely.
The Divider Circuit Is Adopted To Display The Resistance,Eliminate The Influence Of The Power Grid Voltage Fluctuation Effectively,The Extent Of Dependence To The Power Supply Is Low.
Model | RK2678YM |
Output Current | 5~30A ±5% |
Test Accuracy | ±5% |
Resistance | (10.0-199.9)MΩ/(200-600)MΩ |
Test Time | 0.0~999 S±1% 0.0s=Continuous Test |
Transformer Capacity | 1000VA |
Interface Of PLC | Optional |
Power Requirments | 220V±10%50Hz±5% |
Work Environment | 0℃~40℃≤85%RH |
Exterior Dimension | 320x280x180mm |
Weight | 8.5kg |
Accessory | Power Line,Test Line |
Model | Picture | Type | |
RK-16G | Standard | Test Gun | |
RK260100 | Standard | Test Wire | |
RK26103 | Standard | Ground Lead | |
Power Cord | Standard | ||
Warranty Card | Standard | ||
Factory Calibration Certificate |
Standard | ||
Manual | Standard |