RK7505Y/RK7510Y/RK7520Y/RK7530Y/RK7550Y Programmable Medical Leakage Current Tester
Product Introduction
RK7500Y series medical leakage current analyzer, built-in medical simulated human body network, covering ground leakage current, touch current, patient leakage current, patient auxiliary current and other functions, programmable/one-key serialization test
Features
1. Meet the relevant requirements of various standards such as GB4793/GB9706.1-2020
2. Built-in medical simulation human body network
3. The test of ground leakage current, patient leakage current (applying partial grid power supply voltage), patient leakage current (DC and AC) and other items can be completed with one key, and can also be tested by project
4. Test items can be set according to categories, the same test item can be automatically combined and tested, and the measured voltage value, external voltage value, normal leakage current, and single fault state leakage current value can be displayed simultaneously.
5. Leakage current range: support maximum 10mA leakage current RMS range
6. LCD2004C liquid crystal display
7. With 5 groups of memory functions
8. With PLC interface, it can be controlled externally; with RS232C interface, it can upload test data in real time
Model |
RK7505Y |
RK7510Y |
RK7520Y |
RK7530Y |
RK7550Y |
Test device |
Automatic range conversion, true RMS measurement |
||||
Medical GB9706.1-2020 Standard |
Leakage current measurement range AC: I (3~99.9)uA Resolution: 0.1uA |
||||
Ⅱ (100.0~999.9)uA Resolution: 0.1uA |
|||||
Ⅲ (1000~9999)uA Resolution:1uA |
|||||
Patient current, patient auxiliary current: DC Measurement range: (3~999.9)uA Resolution: 0.1uA |
|||||
Measurement accuracy: ±5%+3 digits Note: The accuracy range is current > 10uA or more |
|||||
Frequency response range: DC ~ 1MHz Measurement impedance circuit (MD): in line with GB9706.1-2020 Figure 12 |
|||||
Laboratory GB4793.1-2007 Standard |
Leakage current measurement range AC: I (3~99.9)uA Resolution: 0.1uA |
||||
Ⅱ (100.0~999.9)uA Resolution:0.1uA |
|||||
Ⅲ (1000~9999)uA Resolution:1uA |
|||||
Measurement accuracy: ±5%+3 digits Note: The accuracy range is current > 50uA or more |
|||||
Measuring Impedance Circuit (MD): Compliant with GB4793.1-2007 Figure A.1 |
|||||
The output voltage |
Measure the voltage output range of the power supply: 0V ~ 300V, the resolution is 1V, the accuracy: ± (5% + 2 words) |
||||
Output voltage capacity |
500VA |
1000VA |
2000VA |
3000VA |
5000VA |
Current upper limit setting |
Range: (3~9999)uA Resolution: 1uA Accuracy: ±(4%+3 words) The accuracy range is current>10uA |
||||
timing device |
Range: (3~9999)S Resolution: 1S Accuracy: ±5% |
||||
Operating temperature |
0-40℃ ≤75%RH |
||||
Power requirements |
220±10% 50Hz/60Hz±3Hz |
||||
interface |
Standard RS232, PLC |
||||
Memory group |
five sets of memory |
||||
Screen |
LCD2004C |
||||
Form factor(D×H×W) |
430mm×150mm×350mm |
430mm×150mm×350mm |
430mm×150mm×350mm |
430mm×150mm×350mm |
430mm×150mm×350mm |
weight |
15.3KG |
23KG |
26KG |
30KG |
35KG |
Instrument power consumption |
<50W |
||||
Random standard accessories |
power cable RK00001、RS232 Communication Cable RK00002、RS232 to USB cable RK00003、16G U disk (instruction manual)、Cable interface transfer driver CD、test leadRK00049/RK00050 |
||||
Optional accessories |
host computer |
Model |
picture |
type |
Overview |
test lead RK00049
|
Standard | The instrument comes with a standard test line of 1.2 meters, which can be purchased separately | |
test leadRK00050 |
Standard |
The instrument comes standard with a 1.2-meter test lead, which can be purchased separately | |
USB to square port cable RK00002 |
Standard |
The instrument comes standard with a USB-to-square port cable (host computer) |
|
RS232to USB cable RK00003 |
Standard |
The instrument comes standard with RS232 serial port cable, which can be purchased separately | |
Certificate of Qualification Warranty Card |
Standard |
Instrument standard certificate and warranty card |
|
Factory Calibration Certificate |
Standard |
Instrument standard product calibration certificate | |
PC software |
Includes instruction manual |
Optional |
Instrument optional 16G U disk (including PC software) |
RK00001 |
Optional |
The instrument comes standard with a national standard power cord, which can be purchased separately |