RK2672CY Medical Withstand Voltage Tester
RK2672CY Medical Withstand Voltage Tester
rondedzero yechigadzirwa
RK2672CY yekurapa inomira voltage tester ine mabasa ese eyakajairwa inomira voltage tester, uye inowedzera arc (flashover) yekuona basa.Kuburikidza neoscilloscope yekunze, inogona kuona intuitively, zvakarurama, nekukurumidza uye nekuvimbika kuona "flashover" yezvigadzirwa zvemagetsi pasi pekuedzwa.Kana midziyo yemagetsi iri mukuedzwa isina "flashover" chiitiko, oscilloscope inoratidza yakagadzikana "Lissayut graph (kureva, denderedzwa rakavharwa)".Kana midziyo yemagetsi iri pasi pekuedzwa ine "flashover" chiitiko, kumucheto kweLissajous waveform A jagged shape ichaonekwa, zvichiratidza kuti pane "flashover" mukati memagetsi ekuedzwa.Ichi chigadzirwa chakakodzerawo kune akasiyana siyana emagetsi midziyo inoda kuona "flashover" kukanganisa.Iyo yakakosha kumira voltage tester kune vagadziri vemidziyo yemagetsi ekurapa, madhipatimendi ekugadzirisa, vashandisi, madhipatimendi ekuongorora mhando yechigadzirwa, uye madhipatimendi ekutarisa tekinoroji.
Nzvimbo yekushandisa
Midziyo yekurapa: marudzi ese emidziyo mitsva yekurapa uye midziyo yekutsigira yekurapa, kutarisa kwemoyo, kufungidzira kwekurapa, biochemical yekuongorora michina, eropa rekuona uye ma thermometers uye zvimwe midziyo yekurapa yemumba.
Kuongorora uye michina yekurapa: X-ray yekuongorora uye yekuongorora michina, ultrasound kuongororwa, mushonga wenyukireya, endoscopy system, ENT kuongororwa uye michina yekurapa, dynamic kuongororwa kuongororwa uye michina yekurapa, yakadzika tembiricha firiji michina, dialysis dialysis uye michina yekurapa, yekutanga rubatsiro rwekutanga.
Zvishandiso zvemukoti zvemuchipatara nemidziyo yemagetsi: marudzi ese emibhedha, makabati, macheya ekuvhiya, mibhedha, nezvimwe.
Midziyo yekubatsira: data yehukoti yekurapa uye michina yekugadzira mifananidzo, midziyo yekuvandudza, midziyo yakakosha yevakaremara, nezvimwe.
Midziyo yekurapa yemuromo: midziyo yekurapa yemazino, midziyo yekuvhiya mazino, midziyo yenyanzvi yemazino
Medical Magnetic Resonance Equipment
Maitiro ekuita
1. Nguva yekuedza inogona kusvika 999s
2. Leakage ikozvino, voltage uye nguva zvinoratidzwa panguva imwe chete
3. Leakage ikozvino, nguva yekuedza inogona kuiswa nguva dzose
4. Ne oscilloscope interface, inogona kutarisa chiitiko chekupisa arc uye flashover yechinhu chiri pasi pekuedzwa.
5. GB9706.1-2020 (IEC60601-1: 2012) test voltage zvinodiwa: hapana flashover kana kuputsika kunofanira kuitika panguva yekuedzwa.Iyo yekurapa inomira voltage tester yakanyatso kuwedzera oscilloscope interface kuti itarise iyo flashover uye arc phenomenon kuburikidza neLissajous mifananidzo.
Packing & Shipping
for reference .Wobva waita muripo senzira yaunoda , kana muripo uchinge wasimbiswa , ticharonga kutumira
mukati memazuva matatu.
zvakasimbiswa.
parameter muenzaniso | RK2672CY | |
ACW | Output voltage range | (0.00~5.00)kV |
yakanyanya kubuda simba | 500VA (5.0kV 100mA) | |
Maximum rated current | 100mA | |
Current gear | 2mA, 20mA, 100mA | |
kubuda waveform | Sine wave | |
Output waveform distortion | ≤5% (hapana mutoro kana wakachena resistive mutoro) | |
nguva yekuedza | 0.0S-999S 0=Muedzo unoramba uripo | |
DCW | Output voltage range | (0.00~5.00)kV |
yakanyanya kubuda simba | 100VA (5.0kV 20mA) | |
Maximum rated current | 20mA | |
Current gear | 2mA, 20mA | |
Ripple factor | ≤5% | |
nguva yekuedza | 0.0S-999S 0=Muedzo unoramba uripo | |
Voltmeter | scope | (0.00~5.00)kV |
nemazvo | ±(5%+3 mavara) | |
Resolution | 10V | |
kuratidza kukosha | rms value | |
ammeter | Kuyera chiyero | Range 1: 0.1mA~2mA;Range 2: 2mA~20mA Range 3: 20mA~100mA |
Resolution | 2mA giya: 1uA;20mA giya: 10uA;100mA giya: 0.1mA | |
kuyerwa kwechokwadi | ±(5%+3 manhamba) mukati mechikamu | |
timer | scope | 0.0S-999S |
Minimum resolution | 0.1S | |
nemazvo | ±(1%+50ms) | |
PLC interface | Optional | |
External control interface | Standard | |
Rondedzero yevhoriyamu (D×H×W) | 468mm×196mm×378mm | |
uremu | Inenge 20.65KG | |
Standard accessories | Simba tambo RK00001, high voltage test waya, pasi waya, BNC waya, high voltage pfuti |
Yakanyanya Kururama AC 5KV & AC 100mA Dielectric Inomira Voltage puncture tester / Hipot Tester
Model | Mufananidzo | Type | |
RK-16G | Standard | Test Gun | |
RK260100 | Standard | Test Wire | |
RK26103 | Standard | Ground Lead | |
Tambo yemagetsi | Standard | ||
Warranty Card | Standard | ||
Factory Calibration Certificate | Standard | ||
Manual | Standard |