RK9950 Chirongwa Chinodzorwa Leakage Yazvino Tester
Product Overview
Iyo Programmable Leakage Yazvino Tester ndeye 5-Inch TFT LCD Display.Iyo Tester Inotora 32-Bit Yakakwira-Speed MCU Uye Yakakura-Chiyero Digital Circuit Dhizaini, Yakavakwa MuGB9706.1-2007 (IEC60601-1:1998) Muviri Impedance Simulation Network, Iyo Kadhi MD Network Interface Ine MD-A (Inoenderana ne GB/T12113-2003 Uye GB4793.1-2007)、MD-B(Accord With GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB88113-2007、GB88113-2007、GB4706.1-2005、GB4943.1-2011、GB8811. -2015)), MD-C(Accord With GB/T12113-2003、GB7000.1-2015)、MD-D(Accord With GB4793.1-2007)、MD-E(Accord With GB4943.1-2011、GB4793). 1-2007), MD-F(Accord With GB7000.1-2015).Road Voltage And Current Overrun Protection;MD Network Multiple Fast Dziviriro, Yakachengeteka uye Yakavimbika.Dynamic Uye Static Power Supply Test States;Leakage Yazvino Muedzo Inochinja Otomatiki L (Chikamu Mutsetse) Uye N (Zero Mutsetse).Kugadzika uye Kushanda Kwayo Kwakareruka, Uye Inopa PLC Remote Control Interface, RS232C, RS485, USB Uye Mamwe mainterface, ayo ari nyore kune Vashandisi Kurumidza Kusanganisa MuYakazara Yekuyedza System.
Packing & Shipping
for reference .Wobva waita muripo senzira yaunoda , kana muripo uchinge wasimbiswa , ticharonga kutumira
mukati memazuva matatu.
zvakasimbiswa.
1 、Specific Parameters | |||||
Model | RK9950 (Passive) | RK9950A (500VA) | RK9950B (1000VA) | RK9950C | |
Basic Mabasa | Screen Size | 5-Inch TFT LCD Screen | |||
Number Key | Parameter Setting Digital Input | ||||
Coding Switch | Parameter Sarudzo Uye Kusimbisa Basa | ||||
Kumusoro, Pasi, Kuruboshwe Uye Kurudyi Makiyi Ebasa | Parameter Kumisikidza kumusoro uye pasi Sarudzo Basa | ||||
LOCK Kiyibhodhi Kukiya Basa | Dzivirira Kugadziriswa Kwetsaona Kwemamiriro Ebvunzo Kana Kurambidza Kugadziriswa Kwemamiriro Ebvunzo | ||||
Alarm Basa | Voice Alarm | ||||
Communication Interface | RS232C, RS485, USB | ||||
USB Interface | Kopa, Kopira uye Kuchengeta Mabasa | ||||
Control Interface | HANDLER(PLC) | ||||
Test Method | Dynamic, Static | ||||
Load Voltage (AC) | Range | 0-300V | |||
Kururama | + (2% ×Kukosha Kwekuratidzira +0.5V) | ||||
Frequency | 50/60Hz | ||||
Rodha Yazvino (AC) | Maximum | 25A | |||
Kupfuura Dziviriro Yazvino | Inzwi uye Chiedza Alarm, Cheka Iyo Mutoro Kubuda | ||||
Leakage Current Setting | Upper Limit Setting | ||||
Range | 0.001-20.00mA | ||||
Resolution | <10mA, 0.001/Nhanho>10mA, 0.01mA/Nhanho | ||||
Lower Limit Setting | |||||
Range | 0.000-20.00mA | ||||
Resolution | <10mA, 0.001/Nhanho>10mA, 0.01mA/Nhanho | ||||
Tsanangudzo | Iyo Yepasi Muganho Yakaiswa Ku 0 Pasina Kutongwa | ||||
Leakage Current Measurement | Range Uye Kururama | 0.001-0.050mA DC-10KHz | ± (5% × Kukosha Kwekuratidzira + Mazwi mashanu) | ||
0.050-20.00mA DC-10KHz | ± (2% × Kukosha Kwekuratidzira + Mazwi maviri) | ||||
0.050-20.00mA 10KHz-1MHz | ± (5% × Kukosha Kwekuratidzira + Mazwi mashanu) | ||||
MD Simulated Human Network | 8 Standard Networks | MD-A(GB/T12113-2003、GB4793.1-2007)、MD-B B1(GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、208198、GB4943.1-2011、208198、GB4793.1-2007、GB4793.1-2011、20898) GB7000.1-2015), MD-C(GB/T12113-2003、GB7000.1-2015)、MD-D(GB4793.1-2007)、MD-E(GB4943.1-2011、GB4793.1-200、GB4793.1-200”. )、MD-F(IEC60598-1:2014、GB4793.1-2007)、MD-G(GB4943.1-2011、IEC60950-1:2005、GB4793.1-2007、IEC61010-1:201). | |||
Nguva Yekuedza | Range | Single Time Test: 0.1-999s ± 1%;Nguva Yekuvhara Ndiyo Inoenderera Muedzo | |||
Tsanangudzo | Kana Kuisa 0S Muedzo, Chete N-Waya Inoedzwa, Hapana L Shanduko | ||||
Output Power | Passive | 500VA | 1000VA | Three Phase Passive | |
Kunze Kwemagetsi Kugovera | Kubatana Kwekunze | Built In | Built In | Kubatana Kwekunze | |
2, General Technical Index | |||||
General Technical Index | |||||
Kushanda Tembiricha Uye Humidity | 0℃-40℃,≦75%RH | ||||
Magetsi | 100V-121V, 198V-242V, 47.5-63Hz 5A 250V | ||||
Fuse Size | 5A 250V 10A 110V | ||||
Vhoriyamu Yekunze(D×H×W) | 430mm×105mm×350mm | ||||
Kurema | 13KG | 16KG | 18KG | 14KG |
MODEL | MUFANANIDZO | TYPE | SUMMARY |
RK995001 | Standard | Iyo Chiridzwa Yakashongedzerwa neStandard Power Cable, Iyo Inogona Kutengwa Yakaparadzana. | |
RK20K | Standard | Iyo Chiridzwa Yakashongedzerwa neStandard Data Cable, Iyo Inogona Kutengwa Yakaparadzana. | |
RK00001 | Standard | Iyo Chiridzwa Yakashongedzerwa Neyakajairika Power Cord, Iyo Inogona Kutengwa Yakaparadzana. | |
Certificate Warranty Card | Standard | Instrument Standard Chitupa uye Warranty Card. | |
Factory Calibration Certificate | Standard | Calibration Chitupa cheInstrument Standard Zvigadzirwa. | |
Mirayiridzo | Standard | The Operation Manual yeInstrument Standard Product. | |
PC software | Optional | Chiridzwa chine 16g U disk (kusanganisira yepamusoro komputa software). | |
RS232 kune USB tambo | Optional | Chiridzwa chine RS232 kune USB tambo (yepamusoro komputa). | |
USB kune square port tambo | Optional | Chiridzwa chacho chine USB square port yekubatanidza tambo (yepamusoro komputa). |