RK9950 Program Controlled Leakage Current Tester
Pangkalahatang-ideya ng Produkto
Ang Programmable Leakage Current Tester Ay Isang 5-Inch TFT LCD Display.Ang Tester ay Gumagamit ng 32-Bit High-Speed MCU At Large-Scale Digital Circuit Design,Built In GB9706.1-2007 (IEC60601-1:1998) Body Impedance Simulation Network,Ang Card MD Network Interface ay Naglalaman ng MD-A (Nakaayon sa GB/T12113-2003 At GB4793.1-2007), MD-B(Accord With GB/T12113-2003, GB4793.1-2007, GB4706.1-2005, GB4943.1-201198.1-201198. -2015)、MD-C(Accord With GB/T12113-2003,GB7000.1-2015)、MD-D(Accord With GB4793.1-2007)、MD-E(Accord With GB4943.1-2011,3.GB479. 1-2007)、MD-F(Accord With GB7000.1-2015)。 Load Voltage At Kasalukuyang Overrun Protection;MD Network Maramihang Mabilis na Proteksyon, Ligtas At Maaasahan.Dynamic At Static Power Supply Test States;Ang Leakage Current Test ay Awtomatikong Pinapalitan ang L (Phase Line) At N (Zero Line).Ang Setting At Operasyon Nito ay Napakasimple, At Nagbibigay ng PLC Remote Control Interface, RS232C, RS485, USB At Iba Pang Mga Interface, Na Maginhawa Para sa Mga User Upang Mabilis na Magsama sa Isang Comprehensive Test System.
Pag-iimpake at Pagpapadala
para sa sanggunian . Pagkatapos magbayad ayon sa gusto mo , sa sandaling makumpirma ang pagbabayad , ayusin namin ang shippment
sa loob ng 3 araw.
nakumpirma na.
1, Mga Tukoy na Parameter | |||||
Modelo | RK9950(Passive) | RK9950A(500VA) | RK9950B(1000VA) | RK9950C | |
Mga Pangunahing Pag-andar | Laki ng screen | 5-pulgada na TFT LCD Screen | |||
Susi ng Numero | Pagtatakda ng Parameter Digital Input | ||||
Coding Switch | Parameter Selection At Confirmation Function | ||||
Pataas, Pababa, Kaliwa at Kanan Mga Function Key | Parameter Setting Up At Down Selection Function | ||||
LOCK Keyboard Locking Function | Pigilan ang Aksidenteng Pagbabago Ng Mga Kundisyon ng Pagsubok O Ipagbawal ang Pagbabago Ng Mga Kundisyon ng Pagsubok | ||||
Function ng Alarm | Voice Alarm | ||||
Interface ng Komunikasyon | RS232C, RS485, USB | ||||
USB Interface | Kopyahin, Kopyahin, at Mga Pag-andar ng Imbakan | ||||
Control Interface | HANDLER(PLC) | ||||
Paraan ng Pagsubok | Dynamic, Static | ||||
Boltahe ng Pag-load(AC) | Saklaw | 0-300V | |||
Katumpakan | + (2% ×Display Value +0.5V) | ||||
Dalas | 50/60Hz | ||||
Load Current(AC) | Pinakamataas | 25A | |||
Higit sa Kasalukuyang Proteksyon | Tunog At Banayad na Alarm, Putulin Ang Output ng Pag-load | ||||
Kasalukuyang Setting ng Leakage | Setting ng Upper Limit | ||||
Saklaw | 0.001-20.00mA | ||||
Resolusyon | <10mA,0.001/Step >10mA, 0.01mA/Step | ||||
Setting ng Lower Limit | |||||
Saklaw | 0.000-20.00mA | ||||
Resolusyon | <10mA,0.001/Step >10mA, 0.01mA/Step | ||||
Paliwanag | Ang Mababang Limitasyon ay Itinakda Sa 0 Nang Walang Paghuhukom | ||||
Pagsukat ng Kasalukuyang Paglabas | Saklaw At Katumpakan | 0.001-0.050mA DC-10KHz | ± (5% × Display Value + 5 Words) | ||
0.050-20.00mA DC-10KHz | ± (2% × Display Value + 2 Words) | ||||
0.050-20.00mA 10KHz-1MHz | ± (5% × Display Value + 5 Words) | ||||
MD Simulated Human Network | 8 Mga Karaniwang Network | MD-A(GB/T12113-2003、GB4793.1-2007)、MD-B B1(GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-8.1-2GB4943.1 GB7000.1-2015)、MD-C(GB/T12113-2003、GB7000.1-2015)、MD-D(GB4793.1-2007)、MD-E(GB4943.1-2011,07.1-2011、 )、MD-F(IEC60598-1:2014、GB4793.1-2007)、MD-G(GB4943.1-2011,IEC60950-1:2005,GB4793.1-2007,001.1-2007,IEC60950-1:2005,GB4793.1-2007,001-2007,IEC60950-1:2005,200101-2007,IEC601:2007 | |||
Oras ng Pagsubok | Saklaw | Single Timing Test: 0.1-999s ± 1%;Ang Oras ng Pagsasara ay Tuloy-tuloy na Pagsubok | |||
Paliwanag | Kapag Nagse-set ng 0S Test, N-Wire Lang ang Sinusubukan,Walang L Conversion | ||||
Lakas ng Output | Passive | 500VA | 1000VA | Tatlong Phase Passive | |
Panlabas na Power Supply | Panlabas na Koneksyon | Naka-built In | Naka-built In | Panlabas na Koneksyon | |
2, Pangkalahatang Teknikal na Index | |||||
Pangkalahatang Teknikal na Index | |||||
Temperatura at Halumigmig sa Paggawa | 0℃-40℃,≦75%RH | ||||
Power Supply | 100V-121V,198V-242V,47.5-63Hz 5A 250V | ||||
Sukat ng piyus | 5A 250V 10A 110V | ||||
Panlabas na Dami(D×H×W) | 430mm×105mm×350mm | ||||
Timbang | 13KG | 16KG | 18KG | 14KG |
MODELO | LARAWAN | URI | BUOD |
RK995001 | Pamantayan | Ang Instrumento ay Nilagyan ng Karaniwang Power Cable, Na Maaaring Bilhin nang Hiwalay. | |
RK20K | Pamantayan | Ang Instrumento ay Nilagyan ng Karaniwang Data Cable, Na Maaaring Bilhin nang Hiwalay. | |
RK00001 | Pamantayan | Ang Instrumento ay Nilagyan ng Karaniwang Power Cord, Na Maaaring Bilhin nang Hiwalay. | |
Certificate Warranty Card | Pamantayan | Instrument Standard Certificate At Warranty Card. | |
Sertipiko sa Pag-calibrate ng Pabrika | Pamantayan | Sertipiko ng Pag-calibrate Ng Mga Produktong Pamantayan ng Instrumento. | |
Mga tagubilin | Pamantayan | Ang Operation Manual Ng Instrument Standard Product. | |
PC software | Opsyonal | Ang instrumento ay nilagyan ng 16g U disk (kabilang ang upper computer software). | |
RS232 hanggang USB cable | Opsyonal | Ang instrumento ay nilagyan ng RS232 hanggang USB cable (itaas na computer). | |
USB hanggang parisukat na port cable | Opsyonal | Ang instrumento ay nilagyan ng USB square port connecting cable (itaas na computer). |