I-RK2670Y Medical Withstand Voltage Tester
Isingeniso Somkhiqizo
I-RK2670Y Medical Withstand Voltage Tester Inawo Wonke Umsebenzi We-Conventional Withstand Pressure Tester, Futhi Yandisa Umsebenzi Wokutholwa kwe-Arc(Flashover), Ingahlola I-"Flashover" Yokwenzeka Kwezisetshenziswa Zikagesi Ngomqondo, Ngokunembile, Ngokushesha Futhi Ngokuthembekile Nge-Oscilloscope Yangaphandle. Izisetshenziswa zikagesi ezilinganisiwe Ngaphandle kwe-"Flashover" Phenomenon,Isibonisi se-Oscilloscope "Umfanekiso we-Lissajous Ozinzile"(Indandatho Evaliwe I-IE),Uma Isisetshenziswa Kagesi Senzeka "I-Flashover" Phenomenon,Khona-ke Unqenqema Lomfanekiso we-Lissajous Uzokwenzeka I-"Flashover" Enkulu "I-Flashover" Izinto Ezisetshenziswa Kagesi, Ukuqinisekisa Ukuthi Ukuphepha Kwezisetshenziswa Kagesi Ezilinganisiwe.Lo Mkhiqizo Futhi Ufanele Izisetshenziswa Zikagesi Ezihlukahlukene Ezidingekayo Thola Ukukhubazeka Kwe-"Flashover", IbalulekileMelana neVoltage Tester Of Medical Electrical EquipmentAbakhiqizi, Umnyango Wesondlo, Ukusetshenziswa Kwamayunithi kanye Nomnyango Wokuhlola Ikhwalithi Yomkhiqizo, Iminyango Yokuqondisa Ubuchwepheshe.
Ihambisana Namazinga Ezokwelapha E-GB9706.-2020(IEC60601-1:2012).
Izisetshenziswa Zezokwelapha: zonke Izinhlobo Zamathuluzi Ezokwelapha Amasha Kanye Nezisetshenziswa Zezokwelapha Ezifanisiwe, Ukuqapha Inhliziyo, Ukuthwebula Imifanekiso Yezokwelapha, Amathuluzi Okuhlaziya Amakhemikhali Aphilayo, Imitha Yomfutho Wegazi Kanye Ne-thermometer Kanye Nezinye Izinhlobo Zezinsiza Zezokwelapha Zasekhaya.
Izisetshenziswa Zokuxilonga Nezokwelapha:Ukuxilongwa kwe-X-Ray kanye Nezisetshenziswa Zokuhlola,Ukuxilongwa kwe-Ultrasound,Umuthi Wenuclear,Isistimu ye-Endoscope,Insimbi Yokwelapha ye-ENT,Izisetshenziswa Zokwelapha Ezihlaziya Amandla Kanye Nezisetshenziswa Zesiqandisi Sezinga Eliphansi Lokushisa,Izisetshenziswa Zokwelapha I-Dialysis,Izisetshenziswa Zosizo Lokuqala.
Izinsiza Zokusebeza Esigcemeni Nezisetshenziswa: zonke Izinhlobo Zemibhede Yesibhedlela, Amakhabethe, Izihlalo Ezisebenzayo, Imibhede, Njll.
Izinto Ezisizayo:Idatha Yokunakekelwa Kwezokwelapha Nezisetshenziswa Zokucubungula Izithombe,Izisetshenziswa Zokuvuselela Nezisetshenziswa Ezikhethekile Zabakhubazekile Njll.
Izisetshenziswa Zezokwelapha Zomlomo:Izisetshenziswa Zokuxilonga Zamazinyo,Izinsimbi Zokuhlinza Amazinyo,Izisetshenziswa Zochwepheshe Bamazinyo.
Izisetshenziswa Zezokwelapha Zemagnetic Resonance.
Izimpawu Zokusebenza
N Isikhathi Esikhulu Singafika Kuma-99s.
I-N Ukuvuza Kwamanje, Isikhathi Sokuhlola Singasethwa Ngokuqhubekayo.
I-N GB9701.-2020(IEC60601-1:2012) Izidingo Ze-Voltage Yokuhlola:I-Flash Over Phenomenon Noma Ukwehlukana Akumele Kwenzeke Uma Usesilingo.I-Medical Withstand Voltage TesterKhulisa Ukusebenzelana Kwe-Oscilloscope Ngokukhethekile.Ukubuka I-Flashover Kanye Nokwenzeka Kwe-Arcing Ngomfanekiso we-Lissajous.
I-N Leak Yamanje, I-Voltge, Isibonisi Sesikhathi Ngesikhathi Esifanayo.
N Ine-Oscilloscope Interface, Engaqapha Ukuhlaziya I-Flashover Kanye Ne-Arcing Phenomenon.
Ukupakisha&Ukuthumela
ukuze uthole ireferensi .Bese ukhokha ngendlela othanda ngayo , lapho nje inkokhelo isiqinisekisiwe , sizohlela ukuthunyelwa
phakathi kwezinsuku ezi-3 .
kuqinisekisiwe.
Imodeli | I-RK2670YM | I-RK2672YM | |
I-Voltage ephumayo | AC | 0-5KV | 0-5KV |
DC | —- | 0-5KV | |
Hlola Yamanje | AC | 0-2/20mA | |
DC | —- | 0-2/10mA | |
Hlola Ukunemba | ± (5%+3words) | ||
Isikhathi Sokuhlola | 0.0S-999S 0.0=Isivivinyo Esiqhubekayo | ||
Amandla we-Transformer | 100VA | ||
PLC Interface | Ongakukhetha | ||
Izidingo zamandla | I-AC:220V±10% 50Hz/60Hz±3Hz | ||
Indawo Yokusebenzela | (0-40)℃,≤75% RH | ||
Ubukhulu | 320*270*180mm | ||
Isisindo | 8.5KG | 9.5KG | |
Izesekeli | Izibhamu Zokuhlola Amandla Kagesi Aphezulu, Olayini Be-BNC, Izintambo Zokugawula, Ulayini Wamandla |
Ukunemba Okuphezulu kwe-AC 5KV kanye ne-AC 100mA Dielectric Imelana nesihloli se-Voltage puncture / Isihloli se-Hipot Iyathengiswa
I-wholesale Rek RK2670AM Melana ne-Voltage Tester/Hipot Tester Meter