I-RK2670YM/ RK2672YM Medical Withstand Voltage Tester

I-AC 0-5KV
I-AC 0-20mA/AC 0-20mA DC 0-10mA
0-999S


Incazelo

Ipharamitha

Imininingwane yomkhiqizo

Izesekeli

Ividiyo

I-RK2670Y Medical Withstand Voltage Tester

Isingeniso Somkhiqizo

I-RK2670Y Medical Withstand Voltage Tester Inawo Wonke Umsebenzi We-Conventional Withstand Pressure Tester, Futhi Yandisa Umsebenzi Wokutholwa kwe-Arc(Flashover), Ingahlola I-"Flashover" Yokwenzeka Kwezisetshenziswa Zikagesi Ngomqondo, Ngokunembile, Ngokushesha Futhi Ngokuthembekile Nge-Oscilloscope Yangaphandle. Izisetshenziswa zikagesi ezilinganisiwe Ngaphandle kwe-"Flashover" Phenomenon,Isibonisi se-Oscilloscope "Umfanekiso we-Lissajous Ozinzile"(Indandatho Evaliwe I-IE),Uma Isisetshenziswa Kagesi Senzeka "I-Flashover" Phenomenon,Khona-ke Unqenqema Lomfanekiso we-Lissajous Uzokwenzeka I-"Flashover" Enkulu "I-Flashover" Izinto Ezisetshenziswa Kagesi, Ukuqinisekisa Ukuthi Ukuphepha Kwezisetshenziswa Kagesi Ezilinganisiwe.Lo Mkhiqizo Futhi Ufanele Izisetshenziswa Zikagesi Ezihlukahlukene Ezidingekayo Thola Ukukhubazeka Kwe-"Flashover", IbalulekileMelana neVoltage Tester Of Medical Electrical EquipmentAbakhiqizi, Umnyango Wesondlo, Ukusetshenziswa Kwamayunithi kanye Nomnyango Wokuhlola Ikhwalithi Yomkhiqizo, Iminyango Yokuqondisa Ubuchwepheshe.

Ihambisana Namazinga Ezokwelapha E-GB9706.-2020(IEC60601-1:2012).


750-_英_03
Application Area

Izisetshenziswa Zezokwelapha: zonke Izinhlobo Zamathuluzi Ezokwelapha Amasha Kanye Nezisetshenziswa Zezokwelapha Ezifanisiwe, Ukuqapha Inhliziyo, Ukuthwebula Imifanekiso Yezokwelapha, Amathuluzi Okuhlaziya Amakhemikhali Aphilayo, Imitha Yomfutho Wegazi Kanye Ne-thermometer Kanye Nezinye Izinhlobo Zezinsiza Zezokwelapha Zasekhaya.
Izisetshenziswa Zokuxilonga Nezokwelapha:Ukuxilongwa kwe-X-Ray kanye Nezisetshenziswa Zokuhlola,Ukuxilongwa kwe-Ultrasound,Umuthi Wenuclear,Isistimu ye-Endoscope,Insimbi Yokwelapha ye-ENT,Izisetshenziswa Zokwelapha Ezihlaziya Amandla Kanye Nezisetshenziswa Zesiqandisi Sezinga Eliphansi Lokushisa,Izisetshenziswa Zokwelapha I-Dialysis,Izisetshenziswa Zosizo Lokuqala.
Izinsiza Zokusebeza Esigcemeni Nezisetshenziswa: zonke Izinhlobo Zemibhede Yesibhedlela, Amakhabethe, Izihlalo Ezisebenzayo, Imibhede, Njll.
Izinto Ezisizayo:Idatha Yokunakekelwa Kwezokwelapha Nezisetshenziswa Zokucubungula Izithombe,Izisetshenziswa Zokuvuselela Nezisetshenziswa Ezikhethekile Zabakhubazekile Njll.
Izisetshenziswa Zezokwelapha Zomlomo:Izisetshenziswa Zokuxilonga Zamazinyo,Izinsimbi Zokuhlinza Amazinyo,Izisetshenziswa Zochwepheshe Bamazinyo.
Izisetshenziswa Zezokwelapha Zemagnetic Resonance.

750-_英_09
Izimpawu Zokusebenza
N Isikhathi Esikhulu Singafika Kuma-99s.
I-N Ukuvuza Kwamanje, Isikhathi Sokuhlola Singasethwa Ngokuqhubekayo.
I-N GB9701.-2020(IEC60601-1:2012) Izidingo Ze-Voltage Yokuhlola:I-Flash Over Phenomenon Noma Ukwehlukana Akumele Kwenzeke Uma Usesilingo.I-Medical Withstand Voltage TesterKhulisa Ukusebenzelana Kwe-Oscilloscope Ngokukhethekile.Ukubuka I-Flashover Kanye Nokwenzeka Kwe-Arcing Ngomfanekiso we-Lissajous.
I-N Leak Yamanje, I-Voltge, Isibonisi Sesikhathi Ngesikhathi Esifanayo.
N Ine-Oscilloscope Interface, Engaqapha Ukuhlaziya I-Flashover Kanye Ne-Arcing Phenomenon.

 

Ukupakisha&Ukuthumela

Izitifiketi
FAQ
1.Ingabe izingxenye zakho zintsha futhi zangempela?
Impendulo : Yebo !Izingxenye zethu zingamukela noma yiziphi izinhlobo zokuhlola , uma kukhona izinkinga zekhwalithi sizoziphendulela .
2.Iyini iwaranti yakho?
Impendulo : Zingakapheli izinsuku ezingama-60 ngemuva kokutholwa kwephakheji.
3.Uyikhokha kanjani i-oda?
Impendulo : Singamukela i- TT , Escrow , , Western Union kanye ne- Alipay .Ngemva kokuba i-oda seliqinisekisiwe i-invoyisi izothunyelwa
ukuze uthole ireferensi .Bese ukhokha ngendlela othanda ngayo , lapho nje inkokhelo isiqinisekisiwe , sizohlela ukuthunyelwa
phakathi kwezinsuku ezi-3 .
4.Izinkinga zekhwalithi
Impendulo : Uma kukhona izinkinga zekhwalithi noma imibuzo , singahlinzeka ngosekelo lobuchwepheshe noma isevisi yokubuyisela .
5.Yini isikhathi sakho sokuhola?
Impendulo :Azikho izikhathi zokuhola zemikhiqizo esesitokweni.Izingxenye eziningi zingathunyelwa zingakapheli izinsuku ezi-3 ngemuva kokukhokha
kuqinisekisiwe.
6.Ngingathola isampula ukuze ngihlolwe ?
Impendulo : Yebo!Ukukhokha kuphela izindleko zokuthumela, amasampula wamahhala angathunyelwa ukuze ahlolwe.
7.Ukuthumela:
UPS / Fedex / DHL / TNT / EMS.Pls xhumana nathi ngqo ngendlela oyithandayo.

  • Okwedlule:
  • Olandelayo:

  •  

    Imodeli I-RK2670YM I-RK2672YM
    I-Voltage ephumayo AC 0-5KV 0-5KV
    DC —- 0-5KV
    Hlola Yamanje
     
    AC 0-2/20mA
    DC —- 0-2/10mA
    Hlola Ukunemba ± (5%+3words)
    Isikhathi Sokuhlola 0.0S-999S 0.0=Isivivinyo Esiqhubekayo
    Amandla we-Transformer 100VA
    PLC Interface Ongakukhetha
    Izidingo zamandla I-AC:220V±10% 50Hz/60Hz±3Hz
    Indawo Yokusebenzela (0-40)℃,≤75% RH
    Ubukhulu 320*270*180mm
    Isisindo 8.5KG 9.5KG
    Izesekeli Izibhamu Zokuhlola Amandla Kagesi Aphezulu, Olayini Be-BNC, Izintambo Zokugawula, Ulayini Wamandla

    Ukunemba Okuphezulu kwe-AC 5KV kanye ne-AC 100mA Dielectric Imelana nesihloli se-Voltage puncture / Isihloli se-Hipot Iyathengiswa750750-153750-_144

    imodeli isithombe uhlobo Uhlolojikelele
    I-RK-16G   Okujwayelekile Ithuluzi liza elijwayelekile nesibhamu sokuhlola isilawuli kude esinamandla kagesi aphezulu, esingathengwa ngokuhlukana.
    I-RK26701   Okujwayelekile Ithuluzi liza elijwayelekile elinentambo ye-BNC eneziphetho ezimbili, engathengwa ngokuhlukana.
    I-RK26103   Okujwayelekile Ithuluzi liza elijwayelekile elinomthofu wokuhlola umhlabathi, ongathengwa ngokuhlukana.
    I-RK26101   Okujwayelekile Ithuluzi liza elijwayelekile nemikhondo yokuhlola engathengwa ngokuhlukana.
    RK00001   Okujwayelekile Ithuluzi liza elijwayelekile nentambo yamandla kazwelonke ejwayelekile, engathengwa ngokuhlukana.
    Isitifiketi Sesiqinisekiso Sekhadi Lesiqinisekiso   Okujwayelekile Ithuluzi liza elijwayelekile nesitifiketi sokuvumelana nekhadi lewaranti.
    Isitifiketi Sokulinganiswa Kwemboni   Okujwayelekile Ithuluzi liza elijwayelekile nesitifiketi sokulinganiswa komkhiqizo.
    imanuwali   Okujwayelekile Ithuluzi liza nemanuwali yemiyalelo yomkhiqizo njengokujwayelekile.
    Ibhokisi lokuhlola uchungechunge lwe-RK101   Ongakukhetha Ukuze uthole imininingwane, bheka isihloli sokunamathiselwe.
    RK00002  khipha (1) Ongakukhetha Ikhebuli yesixhumi esibonakalayo ye-PLC yethuluzi idinga ukuthengwa ngokuhlukana.

    I-wholesale Rek RK2670AM Melana ne-Voltage Tester/Hipot Tester Meter

    Thumela umlayezo wakho kithi:

    Bhala umyalezo wakho lapha futhi usithumelele wona
    • facebook
    • linkedin
    • youtube
    • i-twitter
    • blogger
    Imikhiqizo efakiwe, Imephu yesayithi, I-Digital High Voltage Meter, High Voltage Meter, I-High Static Voltage Meter, I-High-Voltage Digital Meter, High Voltage Calibration Meter, Imitha ye-Voltage, Yonke Imikhiqizo