I-RK2672CY Medical Withstand Voltage Tester
I-RK2672CY Medical Withstand Voltage Tester
incazelo yomkhiqizo
I-RK2672CY i-medical standstand voltage tester inayo yonke imisebenzi ye-voltage tester evamile, futhi yengeza umsebenzi wokuthola i-arc (flashover).Nge-oscilloscope yangaphandle, ingakwazi ukubona intuitively, ngokunembile, ngokushesha nangokuthembekile "i-flashover" yemishini kagesi ngaphansi kokuhlolwa.Uma izinto zikagesi ezivivinywayo zingenayo into ethi "flashover", i-oscilloscope ibonisa "igrafu ye-Lissayut (okungukuthi, indilinga evaliwe)" ezinzile.Uma izinto zikagesi ezivivinywayo zinento ethi "flashover", unqenqema lwe-waveform ye-Lissajous Umumo omangelengele uzovela, okubonisa ukuthi kukhona "i-flashover" ngaphakathi kwezinto zikagesi ezivivinywayo.Lo mkhiqizo ubuye ulungele imishini ehlukahlukene kagesi edinga ukubona amaphutha e- "flashover".Kuyi-voltage tester ebaluleke kakhulu yabakhiqizi bemishini kagesi yezokwelapha, iminyango yokulungisa, abasebenzisi, iminyango yokuhlola ikhwalithi yomkhiqizo, kanye neminyango yokuqondisa ubuchwepheshe.
Inkambu yohlelo lokusebenza
Imishini yezokwelapha: zonke izinhlobo zemishini yezokwelapha emisha kanye nemishini esekela ukwelashwa, ukuqapha inhliziyo, izithombe zezokwelapha, imishini yokuhlaziya i-biochemical, iziqapha zomfutho wegazi kanye nama-thermometers nezinye izinto zokwelashwa zasekhaya.
Imishini yokuhlola nokwelapha: Imishini yokuhlola i-X-ray kanye nemishini yokuhlola, ukuxilongwa kwe-ultrasound, imithi yenuzi, isistimu ye-endoscopy, imishini yokuxilongwa kwe-ENT kanye nemishini yokwelapha, ukuxilongwa okuguquguqukayo kokuxilongwa kanye nemishini yokwelapha, imishini yesiqandisi ephansi, ukuxilongwa kwe-dialysis kanye nemishini yokwelapha, imishini yosizo lokuqala.
Imishini yokunakekela esibhedlela kanye nemishini: zonke izinhlobo zemibhede, amakhabethe, izihlalo zokuhlinza, imibhede, njll.
Imishini yokusiza: idatha yabahlengikazi bezokwelapha kanye nemishini yokucubungula izithombe, imishini yokuvuselela, imishini ekhethekile yabakhubazekile, njll.
Imishini yezokwelapha ngomlomo: imishini yezokwelapha yokuxilonga amazinyo, okokuhlinza amazinyo, okokusebenza kochwepheshe bamazinyo
Izisetshenziswa Zezokwelapha Zemagnetic Resonance
Izici zokusebenza
1. Isikhathi sokuhlola singafinyelela kuma-999s
2. Ukuvuza kwamanje, i-voltage kanye nesikhathi kuboniswa ngesikhathi esifanayo
3. Ukuvuza kwamanje, isikhathi sokuhlola singasethwa ngokuqhubekayo
4. Nge-oscilloscope interface, ingakwazi ukuqapha ukwenzeka kwe-ignition arc kanye ne-flashover yento evivinywayo.
5. I-GB9706.1-2020 (IEC60601-1:2012) izidingo ze-voltage yokuhlola: akukho flashover noma ukuphazamiseka okufanele kwenzeke ngesikhathi sokuhlolwa.Umhloli wezokwelapha we-voltage wengeze ngokukhethekile isixhumi esibonakalayo se-oscilloscope ukuze ubuke i-flashover kanye ne-arc phenomenon ngezithombe ze-Lissajous.
Ukupakisha&Ukuthumela
ukuze uthole ireferensi .Bese ukhokha ngendlela othanda ngayo , lapho nje inkokhelo isiqinisekisiwe , sizohlela ukuthunyelwa
phakathi kwezinsuku ezi-3 .
kuqinisekisiwe.
imodeli yepharamitha | I-RK2672CY | |
I-ACW | Ibanga le-voltage yokuphumayo | (0.00–5.00)kV |
amandla okukhipha aphezulu | 500VA (5.0kV 100mA) | |
Isilinganiso esiphezulu samanje | 100mA | |
Igiya lamanje | 2mA, 20mA, 100mA | |
ukuphuma kwe-waveform | Sine wave | |
Okukhiphayo ukuhlanekezela kwe-waveform | ≤5% (awukho umthwalo noma umthwalo oqinile ophikisayo) | |
isikhathi sokuhlola | 0.0S-999S 0=Ukuhlolwa okuqhubekayo | |
I-DCW | Ibanga le-voltage yokuphumayo | (0.00–5.00)kV |
amandla okukhipha aphezulu | I-100VA (5.0kV 20mA) | |
Isilinganiso esiphezulu samanje | 20mA | |
Igiya lamanje | 2mA, 20mA | |
I-Ripple factor | ≤5% | |
isikhathi sokuhlola | 0.0S-999S 0=Ukuhlolwa okuqhubekayo | |
I-Voltmeter | ububanzi | (0.00–5.00)kV |
ukunemba | ±(5%+3 izinhlamvu) | |
Isixazululo | 10V | |
ivelu yokubonisa | rms inani | |
i-ammeter | Ibanga lokulinganisa | Ububanzi 1: 0.1mA~2mA;Ibanga 2: 2mA~20mA Ibanga 3: 20mA~100mA |
Isixazululo | Igiya le-2mA: 1uA;Igiya le-20mA: 10uA;Igiya le-100mA: 0.1mA | |
ukunemba kwesilinganiso | ±(amadijithi angu-5%+3) phakathi kobubanzi | |
isibali sikhathi | ububanzi | 0.0S-999S |
Ukulungiswa okuncane | 0.1S | |
ukunemba | ±(1%+50ms) | |
I-PLC interface | Ongakukhetha | |
Isixhumi esibonakalayo sokulawula sangaphandle | Okujwayelekile | |
Ivolumu yohlaka (D×H×W) | 468mm×196mm×378mm | |
isisindo | Cishe 20.65KG | |
Izesekeli ezijwayelekile | Intambo yamandla engu-RK00001, intambo yokuhlola amandla kagesi aphezulu, intambo yaphansi, intambo ye-BNC, isibhamu esiphezulu |
Imodeli | Isithombe | Uhlobo | |
I-RK-16G | Okujwayelekile | Test Gun | |
I-RK260100 | Okujwayelekile | Intambo Yokuhlola | |
I-RK26103 | Okujwayelekile | I-Ground lead | |
Intambo Yamandla | Okujwayelekile | ||
Ikhadi lewaranti | Okujwayelekile | ||
Isitifiketi Sokulinganiswa Kwemboni | Okujwayelekile | ||
Imanuwali | Okujwayelekile |