I-RK2675Y/ RK2675Y-1/ RK2675Y-2/ RK2675Y-3/ RK2675Y-5 Umhloli Wamanje Wokuvuza Kwezokwelapha
Isingeniso Somkhiqizo
I-RK2675Y I-Medical Leakage Yamanje Yochungechunge Luyisisetshenziswa Sokuhlola Esisetshenziswa Ukulinganisa Ukuvuza Okuqhubekayo Kwamanje Nesisizi Sesiguli Sezisetshenziswa Kagesi Zezokwelapha.Idizayina Nemikhiqizo Ngokuvumelana Ne-GB9706.1_2020 (IEC60601-1:2012).Futhi I-Test Circuit (MD)Input Impedance Yokulingisa Ukuthikamezeka Komzimba, Ihambisana Nezimfuneko Ze-GB9706.1-2020 (IEC60601-1:2012), Ukuhlolwa Kwamanje Kungagijima Kufike Ku-5A, Futhi Kunikeze Abasebenzisi Ngokuzihlukanisa Power Supply Yikuphi Adjustable Okukhipha Voltage For 0 ~ 250V Ngokuqhubekayo Of The Basic Capacity Ukucushwa For The 500VA Futhi Nikeza Omunye 110% Voltage Umthombo We-Maximum Rated Voltage.It Inganelisa I,II, Izinhlobo Ezihlukahlukene Zokuhlola Izinsiza Umhlaba Ukuvuza Kwamanje, Ukuvuza KweShell Okwamanje, Ukuvuza Kwesiguli Kwamanje, Ukuvuza Kwesisizwa Sesiguli Okwamanje Ngaphansi Kwesimo Esivamile Kanye Nephutha Elilodwa.
Application Area
Izisetshenziswa Zezokwelapha: zonke Izinhlobo Zamathuluzi Ezokwelapha Amasha Kanye Nezisetshenziswa Zezokwelapha Ezifanisiwe, Ukuqapha Inhliziyo, Ukuthwebula Imifanekiso Yezokwelapha, Amathuluzi Okuhlaziya Amakhemikhali Aphilayo, Imitha Yomfutho Wegazi Kanye Ne-thermometer Kanye Nezinye Izinhlobo Zezinsiza Zezokwelapha Zasekhaya.
Izisetshenziswa Zokuxilonga Nezokwelapha:Ukuxilongwa kwe-X-Ray kanye Nezisetshenziswa Zokuhlola,Ukuxilongwa kwe-Ultrasound,Umuthi Wenuclear,Isistimu ye-Endoscope,Insimbi Yokwelapha ye-ENT,Izisetshenziswa Zokwelapha Ezihlaziya Amandla Kanye Nezisetshenziswa Zesiqandisi Sezinga Eliphansi Lokushisa,Izisetshenziswa Zokwelapha I-Dialysis,Izisetshenziswa Zosizo Lokuqala.
Izinsiza Zokusebeza Esigcemeni Nezisetshenziswa: zonke Izinhlobo Zemibhede Yesibhedlela, Amakhabethe, Izihlalo Ezisebenzayo, Imibhede, Njll.
Izinto Ezisizayo:Idatha Yokunakekelwa Kwezokwelapha Nezisetshenziswa Zokucubungula Izithombe,Izisetshenziswa Zokuvuselela Nezisetshenziswa Ezikhethekile Zabakhubazekile Njll.
Izisetshenziswa Zezokwelapha Zomlomo:Izisetshenziswa Zokuxilonga Zamazinyo,Izinsimbi Zokuhlinza Amazinyo,Izisetshenziswa Zochwepheshe Bamazinyo.
Izisetshenziswa Zezokwelapha Zemagnetic Resonance
Izimpawu Zokusebenza
N Ukuvuza Kwamanje Kuhlinzeka Ngesethi Yokuhlinzekwa Kwamandla, Kanye Nesethi Yokuhlinzekwa Kwamandla Kwangaphandle Lapho Kuvivinywa.
N Nikeza Ngenani Elimaphakathi,Inani Elisebenzayo,Inani Eliphakeme,DC Lezi Zindlela Ezine Zokutholwa
N Nikeza Ngesilinganiso Samanje Sokuhosha Okuqhubekayo, Ukuvuza Kwesheli Kwamanje, Ukuvuza Kwesiguli Kwamanje, Ukuvuza Kwesizwa Kwesiguli Kwamanje Ngaphansi Kwesimo Esivamile Kanye Nephutha Elilodwa.
N Isikhathi esiphezulu singagijima sifike kuma-99s.
I-N Ukuvuza Kwamanje, I-Voltage, Isibonisi Sesikhathi Ngesikhathi Esifanayo.
I-N Ukuvuza Kwamanje, Isikhathi Sokuhlola Singasethwa Ngokuqhubekayo.
Imodeli | I-RK2675Y | I-RK2675Y-1 | I-RK2675Y-2 | I-RK2675Y-3 | I-RK2675Y-5 |
Test Voltage | 0~250V | ||||
Hlola Yamanje | AC/DC:0~200μA AC/DC:0.2–2mA AC:2–10mA | ||||
Hlola Ukunemba | ±( 5%+3 Amagama) | ||||
Isikhathi Sokuhlola | 0~99s (Iyalungiseka Ngokuqhubekayo) | ||||
Amandla we-Transformer | 500VA | 1000VA | 2000VA | 3000VA | 5000VA |
I-Waveform ephumayo | I-Sine Wave | ||||
Izidingo zamandla | 220V 10%50Hz 2% | ||||
Indawo yokusebenza | 0℃~40℃ ≤75%RH | ||||
Ubukhulu bangaphandle(mm) | 380×290×200 | 430×370×200 | 443×390×200 | 510×430×230 | 550×450×300 |
Isisindo | 11Kg | 24.5Kg | 42Kg | 42Kg | 62Kg |
Isesekeli | Ulayini Wamandla, Isiqeshana Sengwenya |
Imodeli | Isithombe | Uhlobo | |
I-RK-26004C | Okujwayelekile | ||
Intambo Yamandla | Okujwayelekile | ||
Ikhadi lewaranti | Okujwayelekile | ||
Imanuwali | Okujwayelekile
|